My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-18-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
S
>
Saint Andrews Street
>
4665 St. Andrews Street - 06-117-23-31-0012
>
Septic
>
10-18-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:15:16 PM
Creation date
10/5/2021 10:51:17 AM
Metadata
Fields
Template:
x Address Old
Address
4665 St. Andrews St
Document Type
Septic
PIN
0611723310012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4665 5t. Andrews Street INSPECTOR CHECKLIST - mound <br />WELL setbacks: 20' to pressure tested sewer tine (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch. <br />LAKE/ BLUFF setback: 20' for bluff. Lakes: GD _, RD _, NE _. Protected wetland _ <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure sc 10' to bed,tank Et sewer line. (else sewer line n 12" below) <br />Sewer line Et baffle connection (no 90's, T between 45's, slope min 1" in 8', max 2" in 8') <br />(no depth reqs, clean out every 100', Sch 40 pipe) <br />Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg 2250 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Et alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />mfg 1250 gallons <br />0 dose pump 19 gpm ###### head VERIFY PUMP CURVE ##### min ON ###### hr OFF <br />float setting drop ##### inches at 25.5 gpi "DESIGNED" ##### inches approx float tether length <br />##### gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1/8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 32.0 <br />Sand lift depth 18 inches. (.far test : 2" sand leaves < 1 /8" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br />Bermed topsoil beyond rockbed 11 upslope 17 sideslope 20.02 downslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe Ft fittings) <br />3.0 ft lateral spacing <br />7/32 inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary �Re-use existing tank certification <br />monitoring plan and type <br />well abandonment form - if necessary <br />
The URL can be used to link to this page
Your browser does not support the video tag.