03-28-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Court
>
4315 Lakeview Court - 06-117-23-43-0015
>
Septic
>
03-28-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:01 PM
Creation date
10/5/2021 10:46:19 AM
Metadata
Fields
Template:
x Address Old
House Number
4315
Street Name
Lakeview
Street Type
Court
Address
4315 Lakeview Ct
Document Type
Septic
PIN
0611723430015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />3u7o Larger LdnK W1 U1 rnuiLipie comp/ Lan KS <br />1250 gallon Dose tank (minimum) at 25.49 gpi <br />36 GPM @ 28 ft. of head, Pump required <br />8.0 inch swing on Demand float which translates to roughly 5.0 inches of float tether length <br />if time dosing is required -->5.7 minutes ON time Et ®hours OFF time <br />20 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />23 linches from bottom of tank to "Hi Level Alarm" or 1 33 linches to "Hi level alarm" if time dosed <br />95 ft. of 2.0 inch supply linE with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />12 inch, or 1.8 ft. Sand Lift Mound <br />10.0 ft. wide by 62.5 ft. long Rock bed <br />3 laterals 2.00 inch diameter 60.5 ft. long 3.Q ft. lateral spacing <br />7132 inch perfs 3.0 ft. perforation spacing <br />Na Effluent filter Et alarm <br />3 clean out Et valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.Q ft. Downslope I,a,,.d . yore <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 10 ft. upslope berm <br />3:1 sideslope 16 ft. sideslope berms <br />3:1 downslope 30 ft. downslope berm <br />4" inspection pipe <br />18- cover on top <br />Upslope berin =--,,j b Downslope berm/ 30 <br />12" cover on sides <br />(6" Foamy cap & 6" topsoil) <br />1.8 Clean sand lift <br />e 1.2 Depth to Limiting <br />I. Absorption Width <br />Note: <br />For 0 to 1%slopes, Absorption Width is measured from the BedegUally in both directions. <br />For slopes %1%, Abs-oivtrora Width is measured downhill from the upslope edge of the Bed <br />Rock Bed: 21.0 yd or *1.4= 29 ton <br />Mound Sand: 340 yd or *1.4= 476 ton <br />Loamy Cap: 93 yd or "1.4= 130 ton <br />Topsoil: 105 yd3 or *1.4= 147 ton <br />6 inches under pipe <br />calculation based on 3:1!4:1 slope from top of rockbei <br />6" deep <br />6" deep <br />