My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
03-28-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Court
>
4315 Lakeview Court - 06-117-23-43-0015
>
Septic
>
03-28-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:01 PM
Creation date
10/5/2021 10:46:19 AM
Metadata
Fields
Template:
x Address Old
House Number
4315
Street Name
Lakeview
Street Type
Court
Address
4315 Lakeview Ct
Document Type
Septic
PIN
0611723430015
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound design <br />wwuv.5epticResource.com (vers 15.2) <br />Property Owner: Swanson Homes <br />Site Address: 4315 Lakeview Court <br />Comments: <br />Date: 3/27/2019 <br />PID: 0611723430015 <br />instructions: = = enter data = adjust if desired = = computer calculated - DO NOT CHANGE! <br />1)bedroom Type Residential System <br />2) 750 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />s) 1.2 GPD/ft2 mound sand loading rate contour loading rate of =req's a min 62.5 ft. long rockbed <br />6) 10.0 ft rockbed width 62.5 ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />8)laterals 60.5 feet long 21.0 perfs / lateral 63 1perfs total <br />(1 /2 a perf means the first pert starts at the middle feed manifold) <br />9) 7/32 inch perfs at feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size Et spacing, & pipe size on line 12, max perfs/lateral = =1 line #8 must be less > <br />10) 4.0 doses per day (4 minimum) <br />11) 188 gallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />«) 95 feet of 2.0 inch supply line leads to =gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 204 gallons TOTAL pump out volume (treatment + drainback) <br />l5) 19 feet vertical lift from pump to mound laterals, leads to a: <br />16) 36 GPM @ 28 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 750 gal Dose tank (code minimum) 125fl gal Dose tank (design size / LUG req'd) at 25.49 gpi <br />leads to a <br />18) 8.0 inch swing on Demand float, or timed dosing of5.7 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow)i T lhrs OFF test and adjust as necessary) <br />l9)[flinches <br />inches from bottom of tank to '"Pump OFF" float <br />10) inches from bottom of tank to "Pump ON" float, orP33 <br />inches to "Timer ON" float if time dosed <br />21) from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed <br />22) 664 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.