10-16-2017 Septic Design
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2280 Fox Street - 03-117-23-32-0014
>
Land Use
>
10-16-2017 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:33 PM
Creation date
10/5/2021 10:40:46 AM
Metadata
Fields
Template:
x Address Old
House Number
2280
Street Name
Fox
Street Type
Street
Address
2280 Fox St
Document Type
Land Use
PIN
0311723320014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2000 gallon Septic tank (minimum) Tank options: none <br />1000 gallon Dose tank (minimum) at F2 7T. 7-81 g p i <br />E�inch <br />GPM C 24 ft. of head, Pump required <br />swing on Demand float which translates to roughly 2.4 inches of float tether length <br />if time dosing is required - >2.SnLnutes ON time Ft 5.2 1 hours OFF time <br />21 inches from bottom of tank to "pump ON" float, or L 18 inches to "timer ON" float <br />24 inches from bottom of tank to "Hi Level Alarm" or 34 inches to "Hi leve[ alarm" if time dosed <br />b0 ft. of 2.0 inch supply line with lend feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />24 inch, or 2.0 ft. Sand Lift Mound <br />10. D ft. wide by 40.0 ft. long Rock bed <br />3 laterals 1.50 inch diameter 38,0 ft. long =ft. lateral spacing <br />114" inch perfs 3.0 ft, perforation spacing <br />No Effluent filter & alarm <br />3 clean out lY valve box assemblies <br />27.D <br />ft -Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.Q ft. Downstope (sand beyond rockbed, minimun- j <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 14 ft. upslope berm <br />21: <br />4:1 sideslope 17 ft. sideslope berms <br />4:1 downslope 21 ft. downslope berm <br />UDsiope berm <br />PKII <br />4 inspection pipe <br />r— 18" cower on top <br />Clean sand lift <br />Depth to Urniting <br />------------- <br />Absorption Width 27 <br />Dosvnslove berm 21 <br />12" cover on sides <br />(6" loamy cap & 6"° topsoq) <br />Mote: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption Widtb is measured downhill from the upstope edge of the Bed <br />Rock Bed: 18.0_ yd3 or `1.4= 2.5 ton <br />Mound Sand: 201 yd or *1 A= 281 ton <br />Loamy Cap: 64 yd or `1.4= 90 ton <br />Topsoil: 74 yd3 or "1.4= 104 ton <br />inches under pipe <br />calculation based on 3:114:1 slope from top of rockbe <br />b" deep <br />b" deep <br />