My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-16-2017 Septic Design
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2280 Fox Street - 03-117-23-32-0014
>
Land Use
>
10-16-2017 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:33 PM
Creation date
10/5/2021 10:40:46 AM
Metadata
Fields
Template:
x Address Old
House Number
2280
Street Name
Fox
Street Type
Street
Address
2280 Fox St
Document Type
Land Use
PIN
0311723320014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR CHECKLIST - mound <br />ZZ8U Fox Street <br />F7 WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes & bounds: out of road easement, or outer ditch. <br />LAKE 1 BLUFF setback: 20' for bluff. Lakes: GD , RD NE Protected wetland <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure;, 10' to bed,tank Et sewer line. (else sewer dine > 12" below) <br />Sewer line & baffle connection (no 90's, T between 45's, slope min 1" in 8', max 2" in 8') <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />Q Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg 2000 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Et alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />Mfg, 1000 gallons <br />dose pump 29 gpm 24 head VERIFY PUMP CURVE 2.6 min ON 5.2 hr OFF <br />float setting drop 2.7 inches at 27.8 gpi "DESIGNED" 2.4 inches approx float tether length <br />74.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 118"+, supported by 4" sch4D sleeve or compacted, and buried 6"+. <br />splice box 1 control panel 1 electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 40.0 <br />Sand Lift depth 24 inches. (Jar test : 2" sand leaves < 118" silt after 30 min) <br />Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br />❑ Bermed topsoil beyond rockbed 14 upslope 17 sideslope 21 downslope <br />cover depth of 12.18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />1.50 inch pipe size (Sch40 pipe & fittings) <br />3.0 ft lateral spacing <br />rEMM <br />114" inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary <br />monitoring plan and type <br />well abandonment form - if necessary <br />�Re-use existing tank certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.