Septic System Design <br />Additional Information <br />Property <br />Address: 2080 Salem Ct. Orono, MN <br />Description of Waste Water Treatment System <br />This site is an existing home with a failed septic system due to soil separation. The tanks were <br />deemed Compliant by Kothrade Sewer and Water. There is an existing 1000 gallon septic tank <br />and a 1650 gallon dual compartment tank. This tank has the 650 gallon compartment tank as <br />the pump tank. This compartment will be turned into a septic tank and a new 1250 gallon pump <br />tank must be installed. From the proposed 1250 gallon Brown Precast pump tank(Model <br />#1250ST) effluent will be pumped 40 feet to the existing mound. <br />The existing mound is a 1 -foot sand lift mound with a 10'x53' rockbed. The mound will be <br />stripped of all topsoil and loamy cap and set aside. The existing rockbed and laterals will be torn <br />out and disposed of at the proper location. It is an installers decision on how much existing sand <br />to removed before the mound rebuild. It is estimated there is 125 -150 tons of existing sand. <br />Once the mound is stripped of topsoils and existing rockbed, new sand will be installed to a <br />height of 3 feet. Once 3 feet of clean washed sand is established a new 10'x50' rockbed will be <br />installed with new laterals. The existing topsoil and loamy cap can then be re -used as a loamy <br />cap and new top soil must be hauled in. <br />This new on-site sewage treatment system is designed for a 4 bedroom home, Type 3 system in <br />accordance with the MPCA Chapter 7080 and local ordinances. <br />The soils on this site are loamy and clay loams. The periodically saturated soils were located <br />after going to a depth of 0 inches. This will lead 6 inches of usable soil underneath the mound <br />with a 3 sand lift. Therefore providing a 36 inch separation for the treatment of effluent above <br />the periodically saturated soils. <br />1-1000 gallon septic tank will need to be re -used along with the re -used of an the existing 1650 <br />gallon septic/pump tank. A new 1250 gallon pump tank will be installed to lift the sewage to the <br />treatment area. The power supply and switches must be located outside the manhole and <br />pumping chamber in a weather proof enclosure. A warning device must also be installed with <br />audio/visual alerts. The supply line must have drain back to the pumping chamber. <br />From the pump tank sewage will be pumped approximately 40 feet to the mound. There will be <br />3- 2" pipes each 3 feet apart inside the 10' by 50' rockbed. The mound will have a total footprint <br />of 45' by 94' with 5 percent slope underneath it. <br />All tank manholes should be brought to grade upon completion of tank installation, inspection <br />ports for the distribution boxes should also be at grade upon completion. <br />Ende Septic Service, LLC, 24910 Territorial Road I ph.763-428-4489 orinfo(o)endeseotic.com 1 <br />