My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05-02-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
W
>
West Farm Road
>
1860 West Farm Road - 27-118-23-43-0018
>
Septic
>
05-02-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:22:38 PM
Creation date
10/1/2021 4:18:44 PM
Metadata
Fields
Template:
x Address Old
House Number
1860
Street Name
West Farm
Street Type
Road
Address
1860 West Farm Road
Document Type
Septic
PIN
2711823430018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br />www.SeplicResaurce.cam (vers 15.2) <br />Property Owner: Mark Beltrand <br />Site Address: 1860 West Farm Road <br />Date: 11/12/2018 <br />PID: 2711823430018 <br />Comments: �Om i' S i 2I f,-- <br />instructions: = = enter data = adjust if desired = computer calculated - DO NOT CHANGE! <br />1) bedroom Type I ' I Residential System <br />600 GPD design flow <br />Yes Garbage disposal or pumped to septic <br />2254 Gal Septic tank (code minimum) <br />50% larger tank with multiple comp/tanks <br />2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />1.2 GPD/ft7 mound sand loading rate contour loading rate of 12 req's a min 38 ft. long rockbed <br />1D.D ft rockbed width 5D.0 ft rockbed length <br />3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />laterals 48,0 feet long 17.4 perfs / lateral 51 perfs total <br />(1 /2 a pert means the first perf starts at the middle feed manifold) <br />1l4" inch perfs at feet residual head gives 0.74 gpm flow rate per perforation <br />for this pert size Et spacing, Et pipe size on line 12, max perfs/lateral = 25 line #8 must be less > OK <br />10) 4.4 doses per day (4 minimum) <br />11) 150 gallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />13) 200 feet of 2.0 inch supply line leads to 34 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 184 gallons TOTAL pump out volume (treatment + drainback) <br />i5) 18 feet vertical lift from pump to mound laterals, leads to a: <br />]6) 3$ JGPM C 33 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 500 gal Dose tank (code minimum) 1000 gal Dose tank (design size / LUG req'd) at 25.00 gpi <br />leads to a <br />18) 7.4 inch swing on Demand float, or timed dosing of4.8 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow)hrs OFF test and adjust as necessary) <br />l9)12 inches from bottom of tank to "Pump OFF" float <br />20) 19 inches from bottom of tank to "Pump ON" float, or 12 inches to "'Timer ON" float if time dosed <br />21) 22 inches from bottom of tank to "Hi Level" float, or 32 inches to "Hi Level" float if time dosed <br />22) 450 gallons reserve capacity (after High Level Alarm is activated) <br />