05-29-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
P
>
Pinehurst Court
>
690 Pinehurst Court - 06-117-23-33-0014
>
Septic
>
05-29-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:11 PM
Creation date
10/1/2021 3:59:47 PM
Metadata
Fields
Template:
x Address Old
House Number
690
Street Name
Pinehurst
Street Type
Court
Address
690 Pinehurst Ct
Document Type
Septic
PIN
0611723330014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />aUk Ldlger Ld11K WILn MULLlple curllp! Lan KS <br />125b gallon Dose tank (minimum) at LEO <br />36 GPM23 ft. of head, Pump required <br />8.0 inch swing on Demand float which translates to roughly 5.0 inches of float tether length <br />if time dosing is required - ,5.7 minutes ON time & hours OFF time <br />20 inches from bottom of tank to "pump ON" float, or LL12 dinches to "timer ON" float <br />23 inches from bottom of tank to "Hi Level Alarm" or 1 33 1 inches to "Hi level alarm" if time dosed <br />93 ft. of 2.0 inch supply line withend feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />16 inch, or 1.3 ft. Sand Lift Mound <br />10.0 ft, wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter =ft. long 3.0 ft. lateral spacing <br />7132 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter ft alarm <br />3 clean out ft valve box assemblies <br />27,0 ft.Total sand ABSORPTION width (minimum) <br />0.0 Tt. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:9 upslope ratio 10 ft. upslope berm <br />3:1 sideslope 12 ft. sideslope berms <br />4:1 downslope 22 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />Upslope berm =--,, 1� L. Downsloae berm 2z <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />1.3 11 Clean sand lift <br />1.7 r <br />_ — <br />pth to Limiting <br />Limiting Condition Absorption Width 27.0 —� _--_—__ <br />Note: <br />For 0 to 1% slopes, Absorptian Width is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption Width is measured downhill from the upslope edge of the Berl <br />Rock Bed: 21.0 yd or *1.4= 29 ton <br />Mound Sand: 179 yd or *1.4= 251 ton <br />Loamy Cap: 71 yd or *1.4= 99 ton <br />Topsoil: 82 yd or *1.4= 115 ton <br />6 inches under pipe <br />calculation based on 3:1/4:1 slope from top of rockbe <br />6" deep <br />6" deep <br />