Laserfiche WebLink
JOB #2005-01 <br />KSAT TEST DATA SHEET <br />Measurement No. 2 Conducted By <br />Location TP - 1 Date <br />Weather Condition Cloudy Temperature 40's <br />Horizon B <br />Hole Depth 60 cm Measured (Actual) water level in hole <br />Distance between reference level Initial 15 cm <br />and soil surface + 2 cm Final 15 cm <br />Distance from the hole bottom to Radius of the hole ( r ) 2.65 cm <br />Desired water depth in hole (H) - 15 cm <br />Constant-head tube setting (d) = 47 cm <br />Reservoir Used for Measurement of the Steady-State Flow Rate <br />Flow Measuring Reservoir Only <br />Both Flow Measuring and Main Reservoirs X <br />(To obtain flow volume multiply change in water level by the appropriate C.F. from above.) <br />Clock Time <br />Reservoir <br />Reading <br />in Water <br />Level Flow Volume Q Q <br />Ksat <br />h:min cm cm <br />cm3 cm3/min cm <br />3/hr cm/h <br />300 32.9 <br />305 32.1 0.8 84 17 1008 1.14 <br />310 31.5 0.6 63 13 756 0.85 <br />315 30.9 0.6 63 13 756 0.85 <br />320 30.3 0.6 63 13 756 0.85 <br />Ksat = 0.85 cm/h 5.03 gpd/ft2 <br />COMMENTS: <br />cm <br />Peter Miller <br />11/6/2007 <br />min <br />Conversion Factor (C.F.) = 20cm 2 <br />Conversion Factor (C.F.) = 105cm 2 <br />∆t <br />5 <br />5 <br />5 <br />the reference level (D) = 62 <br />Average of Last three measurements: <br />5