My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05-03-2017 Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
300 Big Island - PID: 23-117-23-32-0027
>
Septic
>
05-03-2017 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:13:16 PM
Creation date
10/1/2021 2:52:25 PM
Metadata
Fields
Template:
x Address Old
House Number
300
Street Name
Big Island
Address
300 Big Island
Document Type
Septic
PIN
2311723320027
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
v 07.14.15 <br /> <br />1.A.Design Flow (Design Sum.1A):GPD <br />B.Min. required pump tank capacity:Gal C.Recommended pump tank capacity:Gal <br />D.Pump tank description: <br />MEASURED TANK CAPACITY (existing tanks): <br />2.A.Rectangle area = Length (L) X Width (W) <br />ft X ft =ft2 <br />B.Circle area = 3.14r2 (3.14 X radius X radius) <br />3.14 X 2 ft =ft2 <br />C. <br />ft2 X 7.5 gal/ft3 ÷ 12 in/ft =Gallons per inch <br />D.Calculate Total Tank Volume <br />Depth from bottom of inlet pipe to tank bottom :in <br />Total Tank Volume = Depth from bottom of inlet pipe (Line 4.A) X Gallons/Inch (Line 2) <br />in X Gallons Per Inch = Gallons <br />MANUFACTURER'S SPECIFIED TANK CAPACITY (when available): <br />3.A.Tank Manufacturer: <br />B.Tank Model: <br />C.Capacity from manufacturer:Gallons <br />D.Gallons per inch from manufacturer:Gallons per inch <br />E.Liquid depth of tank from manufacturer:inches <br />4. <br />(Pump and block height + 2 inches) X Gallons Per Inch (2C or 3E) <br />(in +2 inches) X Gallons Per Inch =Gallons <br />5. <br />- Line 17 of the Pressure Distribution or Line 11 of Non-level Gallons (minimum dose) <br />6.Calculate Maximum Pumpout Volume (25% of Design Flow) <br />Design Flow:GPD X =Gallons (maximum dose) <br />7.Gallons <br />8.Calculate Doses Per Day = Design Flow ÷ Delivered Volume <br />Doses <br />9.Calculate Drainback: <br />A.Diameter of Supply Pipe =inches <br />B.Length of Supply Pipe =feet <br />C.Volume of Liquid Per Lineal Foot of Pipe =Gallons/ft <br />D.Drainback = Length of Supply Pipe X Volume of Liquid Per Lineal Foot of Pipe <br />ft X gal/ft =Gallons <br />10.Total Dosing Volume = Delivered Volume plus Drainback <br />gal +gal = Gallons <br />11.Minimum Alarm Volume = Depth of alarm (2 or 3 inches) X gallons per inch of tank <br />in X gal/in = Gallons49.8 <br />Note: Design calculations are based on <br />this specific tank. Substituting a <br />different tank model will change the <br />pump float or timer settings. Contact <br />designer if changes are necessary. <br />1000 <br /> <br /> <br />OSTP Pump Tank <br />Design Worksheet <br />1094 <br />24.9 <br /> <br />398 <br />Select a pumpout volume that meets both Minimum and Maximum: <br />gpd ÷ gal = <br />IM-1060 <br />Calculate Volume to Cover Pump (The inlet of the pump must be at least 4-inches from the bottom of the pump <br />tank & 2 inches of water covering the pump is recommended) <br />DETERMINE DOSING VOLUME <br />44.0 <br />4.4 <br />4 <br />56 <br />0.170 <br /> Minimum Delivered Volume = 4 X Volume of Distribution Piping: <br />24.9 <br />1000 <br />2 <br />60 <br />56 <br />56 <br />26 <br />14 <br />26 <br />4.4 <br />Infiltrator <br />225 <br />56 <br />0.170 <br />0.25 <br />225 <br />2 24.9 <br />Calculate Gallons Per Inch. Multiply the area from 1.A or 1.B, by 7.5 to determine the gallons per foot <br />the tank holds and divide by 12 to calculate the gallons per inch. <br />Project ID: DETERMINE TANK CAPACITY AND DIMENSIONS <br />Demand to Gravity <br /> <br />225 <br />Width <br />Length <br />Radius
The URL can be used to link to this page
Your browser does not support the video tag.