My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
07-20-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road North
>
0315 Old Crystal Bay Road North - 33-118-23-31-0004
>
Septic
>
07-20-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:49:14 PM
Creation date
10/1/2021 1:43:32 PM
Metadata
Fields
Template:
x Address Old
House Number
315
Street Name
Old Crystal Bay
Street Type
Road
Street Direction
North
Address
315 Old Crystal Bay Road North
Document Type
Septic
PIN
3311823310004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2411 purple code Mound Design <br />www.SepticResource.com (uers 15.21 <br />Property Owner: Arta Engleman Date: 7/20/2019 <br />Site Address: 315 Old Crystal Bay Road N. PID: 3311823310004 <br />Comments: <br />instructions: = = enter data = adjust if desired = computer calculated - DO NOT CHANGE! <br />1)bedroom Type Residential System <br />2) 600 GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />4) 2250 Gal Septic tank (code minimum) 225D Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />5) 1.2 GPD/ftZ mound sand loading rate contour loading rate of =req's a min 50 ft. long rockbed <br />b) 10.0 ft rockbed width 50.0 ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />8) laterals 48.0 feet long 17.0 perfs / lateral 51 perfs total <br />(1 /2 a perf means the first perf starts at the middle feed manifold) <br />9) 7/32 inch perfs at feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size la spacing, l* pipe size on line 12, max perfs/lateral = 30 tine #8 must be less --> OK <br />10) 4.4 doses per day ( 4 minimum) <br />)1) 150 gallons per dose (treatment volume) <br />2.00 5x <br />)2) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />13) 265 feet of 2.0 inch supply line leads to 45 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />)4) 195 gallons TOTAL pump out volume (treatment * drainback) <br />)s) 11 feet vertical lift from pump to mound laterals, leads to a: <br />16) 29 IGPM @ 24 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 500 gal Dose tank (code minimum) 1250 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br />Leads to a <br />inch swing on Demand float, or timed dosing of6.7 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow}hrs OFF test and adjust as necessary) <br />�) Ifl <br />inchesfrom bottom of tank to "Pump OFF" float <br />n)inches from bottom of tank to "Pump ON" float, orP33 <br />inches to "Timer ON" float if time dosed <br />z)) inches from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed <br />25) 664 gallons reserve capacity (after High Level Alarm is activated) <br />
The URL can be used to link to this page
Your browser does not support the video tag.