09-13-2019 Septic Design
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road South
>
0225 Old Crystal Bay Road South - 04-117-23-24-0002
>
Septic
>
09-13-2019 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:11:48 PM
Creation date
10/1/2021 1:17:01 PM
Metadata
Fields
Template:
x Address Old
Address
0225 Old Crystal Bay Rd S
Document Type
Septic
PIN
0411723240002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Joseph Olson D.B.A. <br />Rusty Olson's--Soil and Percolation Testing <br />Joseph J. Olson--MPCA License # 810 <br />11481 Riverview Rd, NE, Hanover, MN 55341 <br />(763) 498-8779 Fax (763) 498-8290 <br />July 21, 2018 <br />Gordon James <br />225 Old Crystal Bay Load S. <br />Orono, Hennepin County <br />This on-site Sewage Treatment System is designed for a Type 1 five -bedroom home in accordance with the <br />Minnesota Pollution Control Agency Chapter 7080 and local ordinances. <br />The periodically saturated soils were located at I8-22 inches (mottled soil). The existing mound system is <br />going to be used. <br />The existing septic system does conform to the state code chapter 7080 <br />All neighboring wells are greater than 100' from proposed treatment areas. <br />The soils at a depth of 12" have a percolation rate averaging 3 MPI. <br />The existing septic tanks must be abandoned. New septic tanks need to be installed that meets 2250 -gallon <br />septic tank capacity. <br />All new tanks need to be insulated if there is less than two feet of cover over the top of the tanks. Clean <br />outs must be installed on the end of the laterals for maintenance. <br />A 1300 gallon pumping chamber will need to be installed to lift the effluent to the treatment area. The <br />power supply and switches must be located outside the manhole and pumping chamber in a weatherproof <br />enclosure. A warning device must be installed with light and sound devices; this is in case of a pump <br />failure. A flow measurement device must be installed. Including but not limited to a water meter, event <br />counter, running time clocks or electronically controlled dosing. <br />With proper installation and maintenance, this system should have no problem in treating septic effluent <br />effectively. Nothing other than gray water. (laundry, showers, etc.) Human water and toilet tissue should be <br />disposed of into the septic tanks. Iron filters cannot go into the septic system Garbage disposals are not <br />recommended. Additives must not be used they may cause harmful damage to your septic system. It is <br />recommended that you pump the septic tanks every two years. <br />Sincerely, <br />Joseph J. Olson <br />