My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10-03-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
O
>
Old Crystal Bay Road South
>
0799 Old Crystal Bay Road South - 09-117-23-21-0017
>
Septic
>
10-03-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:18:14 PM
Creation date
10/1/2021 1:08:46 PM
Metadata
Fields
Template:
x Address Old
Address
0799 Old Crystal Bay Rd S
Document Type
Septic
PIN
0911723210017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />375Q gallon Septic tank (minimum) Tank options: none <br />ous, Larger tank wun muaipte comp/ Lanus <br />2000 gallon Dose tank (minimum) at 47.62 gpi <br />56 GPM @ ®ft. of head, Pump required <br />6.7 inch swing on Demand float which translates to roughly 4.4 inches of float tether length <br />if time dosing is required --> 5.7 minutes ON time Et =hours OFF time <br />19 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />22 inches from bottom of tank to "Hi Level Alarm" or 32 inches to "Hi level alarm" if time dosed <br />105 ft. of2.0 inch supply line with middle feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />16 inch, or 1.3 ft. Sand Lift Mound <br />10.0 ft. wide by 100.0 ft. long Rock bed <br />6 laterals 2.00 inch diameter 49.0 ft. long 3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter ft alarm <br />6 clean out a valve box assemblies <br />20.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 Ift. upslope and sideslope (sand beyond rockbed, minimum) <br />10.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil- beyond rockbed) of: <br />E <br />upslope ratio 11 ft. upslope berm <br />sideslope 12 ft. sideslope berms <br />downslope 29 ft. downslope berm <br />4" inspection pipe <br />19' cover on top <br />L. Upslope berm = 'I T 1� 6 Downslope berm 29 <br />12" cover on sides <br />(6" loamy cap &6* topsoil) <br />1.3 11 Clean sand lift <br />1.7 Depth to Limiting - <br />Limiting Condition — __—_`._______— <br />Absorntion Width 20.0 �--- <br />Note: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequatly in both directions. <br />For slopes >1%, Absorption JW&his measured downhill from the upslope edge of the Bed. <br />Rock Bed: 34.0 yd or *1.4= 48 ton 6 inches under pipe <br />Mound Sand: 298 yd or *1.4= 417 ton calculation based on 3:1/4:1 slope from top of rockbei <br />Loamy Cap: 123 yd or *1.4- 172 ton 6" deep <br />Topsoil: 138 yd or *1.4= 193 ton 6" deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.