My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12-05-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
A
>
Augusta Street
>
4775 Augusta Street - 06-117-23-33-0010
>
Septic
>
12-05-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:27:07 PM
Creation date
10/1/2021 11:21:32 AM
Metadata
Fields
Template:
x Address Old
House Number
4775
Street Name
Augusta
Street Type
Street
Address
4775 Augusta St
Document Type
Septic
PIN
0611723330010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />Z)u7a Larger lanK WItn rnuu.ipLe comp/ LarrKs <br />1250 gallon Dose tank (minimum) at 25.49 gpi <br />36 GPM @ 17 ft. of head, Pump required <br />7.6 inch swing on Demand float which translates to roughly 4.8 inches of float tether length <br />if time dosing is required --> 5.4 minutes ON time Ft =hours OFF time <br />20 inches from bottom of tank to "pump ON" float, or 12 1 inches to "timer ON" float <br />23 linches from bottom of tank to "Hi Level Alarm" or 1 33 linches to "Hi level alarm" if time dosed <br />30 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />18 inch, or 1.5 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 61.0 ft. long 3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 Ictean out & valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 10 ft. upslope berm <br />3:1 sideslope 13 ft. sideslope berms <br />4:1 downslope 28 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />U pslope be rm 10 _ t I _ <br />1.5 11 Clean sand lift <br />Downslope berm 1 28 <br />12" cover on sides <br />(6" loamy cap & 6" topsoil) <br />1.5 Depth to Limiting <br />r�nc�itr'an � <br />Absorption Width <br />Note; <br />For 0 to 1 slopes, Absorption W dth is measured from the Bedequally in both directions. <br />For slopes >1%, Absorption .t�4�fdtfr is measured downhill from the upslope edge of the Bea! <br />Rock Bed: 21.0 yd3 or *1.4= 29 ton <br />Mound Sand: 233 yd or *1.4= 326 ton <br />Loamy Cap: 84 yd or *1.4= 118 ton <br />Topsoil: 95 yd or *1.4= 133 ton <br />6 inches under pipe <br />calculation based on 3:1/4:1 slope from top of rockbet <br />6" deep <br />6" deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.