My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-11-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Longview Circle
>
2250 Longview Circle - 03-117-23-22-0008
>
Septic
>
06-11-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:34:32 PM
Creation date
9/30/2021 4:06:24 PM
Metadata
Fields
Template:
x Address Old
House Number
2250
Street Name
Longview
Street Type
Circle
Address
2250 Longview Cir
Document Type
Septic
PIN
0311723220008
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />7Uk Larger LMK WILn MULLIPLe LULFIp! La91Ki <br />1300 gallon Dose tank (minimum) at 25.49 gpi <br />36 GPM C 20 ft. of head, Pump required <br />7.6 inch swing on Demand float which translates to roughly 4.8 inches of float tether length <br />if time daring is required > 5.4 minutes ON time Et ®hours OFF time <br />20 inches from bottom of tank to "pump ON" float, or 12 inches to "timer ON" float <br />23 linches from bottom of tank to "Hi Level Alarm" or 33 inches to "Hi level alarm" if time dosed <br />30 ft. of 2.0 inch supply line with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />16 inch, or 1.3 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2.00 inch diameter 61.4 ft. long 3.0 ft. lateral spacing <br />7132 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 clean out Et valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17,0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 9 It. upslope berm <br />3;1 sideslope 14 fideslope berms <br />3:1 downslope 30 ft. downslope berm <br />4" inspection pipe <br />18" cover on top <br />Upslope herrn I l 41 11 DownsloDe bene 30 <br />12" cover on sides <br />(6" ioaremy cap &. 6" topsoil) <br />1.3 11 Clean sand lift <br />Depth to Limiting <br />!_imrtirlg Condition --- ---------- <br />Absorption Width 127.0 <br />Note: <br />For 0 to 1% slopes, Absorptian Width is measured from the Bedequally in both directions. <br />For slopes a1%, Absorption Width is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 21.0 yd or *1.4= 29 ton <br />Mound Sand: 208 yd or*1.4= 292 ton <br />Loamy Cap: 87 yd3 or *1.4= 122 ton <br />Topsoil; 100 yd or *1.4= 140 ton <br />6 inches under pipe <br />calculation based on 3:114:1 slope from top of rockbei <br />6" deep <br />6" deep <br />