10-18-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
A
>
Augusta Street
>
4710 Augusta Street - 06-117-23-32-0011
>
Septic
>
10-18-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:47 PM
Creation date
9/29/2021 1:55:04 PM
Metadata
Fields
Template:
x Address Old
House Number
4710
Street Name
Augusta
Street Type
Street
Address
4710 Augusta St
Document Type
Septic
PIN
0611723320011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
18 inch, or 1.5 ft. Sand Lift Mound <br />10.0 ft. wide by 62.5 ft. long Rock bed <br />3 laterals 2.00 inch diameter 60,5 ft. long 3.0 ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />FNo7 Effluent filter a alarm <br />=clean out Et valve box assemblies <br />27.0 ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17,0 ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio11 ft, upslope berm <br />4:1 17 sideslope ft. sideslope berms <br />downslope 25 ft. downslope berm <br />4:1 <br />4" inspection pipe <br />18" cover on top <br />berm = _ I 1� I . nnuan-Inna harm F 25 <br />12" cover on sides <br />(6" loamy* cap &6" topsoil) <br />1.5 11 Clean sand lift <br />_ 1.5 Depth to Limiting <br />Absorption Width F701 <br />Note: <br />For 0 to 1% slopes, Absorption Width is measured from the Bedequally in both directions. <br />For slopes A 1 %, Absorption P dtf! is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 21.0 yd3 or "1.4= 29 ton 6 inches under pipe <br />Mound Sand: 235 yd3 or `1.4= 329 ton calculation based on 3:1 /4:1 slope from top of rockbei <br />Loamy Cap: 87 yd3 or "1.4= 122 ton 6" deep <br />Topsoil: 99 yd3 or "1.4= 139 ton 6" deep <br />INSPECTOR CHECKLIST - mound <br />4/1U Augusta Street <br />® WELL setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes & bounds: out of road easement, or outer ditch. <br />LAKE/ BLUFF setback: 20' for bluff. Lakes: GD _, RD—, NE Protected wetland _. <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure- se 10' to bed,tank a sewer line. (else sewer tine > 12" below) <br />❑ Sewer line Et baffle connection (no 90's, 3' between 45's, slope min i" in 8', max 2" in 8') <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg 2250 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent fitter Et alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />