My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
12-06-2017 Septic Design
Orono
>
Property Files
>
Street Address
>
H
>
Hunter Drive
>
1180 Hunter Drive - 25-118-23-42-0006 (Formerally Sixth Ave N)
>
Septic
>
12-06-2017 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:15:11 PM
Creation date
9/29/2021 1:52:09 PM
Metadata
Fields
Template:
x Address Old
House Number
1180
Street Name
Hunter
Street Type
Drive
Address
1180 Hunter Drive
Document Type
Septic
PIN
2511823420006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Installer Summary <br />2250 gallon Septic tank (minimum) Tank options: none <br />:)wo rarger LanK win rnuuipie temp/ Lanrca <br />130Q gallon Dose tank (minimum) at 25.44 gpi <br />36 GPM @ 26 ft. of head, Pump required <br />8.9 inch swing on Demand float which translates to roughly 5.5 inches of float tether length <br />if time dosing is required --> 6.3 minutes ON time ft ®hours OFF time <br />21 inches from bottom of tank to "pump ON'°float, or 12 inches to "timer ON" float <br />24 linches from bottom of tank to "Hi Level Alarm" or 1 34 linches to "Hi level alarm" if time dosed <br />Z38 ft. of Z.Q inch supply HnE with end feed manifold connection <br />(Tip: "top feed" manifold to control drainback) <br />22 inch, or 1.8 ft. Sand Lift Mound <br />10.0 ft. wide by 63.0 ft. long Rock bed <br />3 laterals 2..00 inch diameter 61.0 ft. long =ft. lateral spacing <br />7/32 inch perfs 3.0 ft. perforation spacing <br />No Effluent filter Et alarm <br />3 clean out Et valve box assemblies <br />27.Q ft.Total sand ABSORPTION width (minimum) <br />0.0 ft. upslope and sideslope (sand beyond rockbed, minimum) <br />17.Q ft. Downslope (sand beyond rockbed, minimum) <br />Specific slope ratios give BERM widths (topsoil beyond rockbed) of: <br />4:1 upslope ratio 12 ft. upslope berm <br />3:1 sideslope 1 14 Ift. sideslope berms <br />4:1 downslope 1 27 Ift. downslope berm <br />UDsloDe berm 12 <br />� 1.8 <br />1.2 <br />Limiting Conditi; -- <br />4" inspection pipe <br />r-- 18" cover on top <br />12" cover on sides <br />(6" 1raray cap & 6" topsoil) <br />Clean sand lift <br />[?epth to Limiting <br />--------------- <br />Absorption width 27.0 Y --`---I------- —- <br />Note: <br />For 0 to 1% slopes, Absorptior7 Width is measured from the Bodequally in both directions. <br />For slopes >1%, Abso, ptron 1�fWldth is measured downhill from the upslope edge of the Bed. <br />Rock Bed: 21.0 yd3 or X1.4= 29 ton <br />Mound Sand: 268 yd or *1.4= 375 ton <br />Loamy Cap: 87 yd or "1.4= 122 ton <br />Topsoil: 100 yd3 or *1.4= 140 ton <br />inches under pipe <br />calculation based on 3:1 /4:1 slope from top of rockbei <br />6" deep <br />6" deep <br />
The URL can be used to link to this page
Your browser does not support the video tag.