Laserfiche WebLink
A. 11A. Ende Sep ic Service.LLC1 <br />INDIVIDUAL SEWAGE SYSTEM DESIGN SUMMARY <br />Property Owner: David Gange Phone: 612490-3378 <br />Address: 1140 Wyndmere Rd_ Township: <br />City: Orono Zip: County: Hennepin County <br />DESIGN USAGE SITE CHARACTERISTICS <br />Single Family Home 4 Other Soil type Samdy loam <br />Number of Potential Bedrooms Hydraulic Loading .6 <br />Garbage Disposal no Depth to restrictive layer 18 inches <br />Sewage Lift Pump no <br />PUMP INFORMATION CAPACITIES <br />Pump GPM & TDH 38 gpm and 20 tdh Daily Water Use Est Calc 600 <br />Cycles per day 4 cycles T Septic Tank Capacity 2-1250 gallon tanks -to be installed <br />Gallons per cycle 150 gallons mm T Pump Tank Capacity 1250 gallon tank -to be installed <br />Perforation size & spacing '/4 " perfs every 3 feet MOUND SYSTEM <br />Number, spacing, & <br />diameter of laterals 3-2 inch laterals every 3 feet Dimension of Rock Base 10x50 <br />Depth of Rock Below Pipe 6 inches <br />Mound Materials <br />Amount of Rock 24 tons <br />Amount of Mound sand <br />Amount of loamy cap <br />Amount of topsoil <br />Lineal Feet supply line <br />Lineal Feet Main Line <br />Dimensions of Mound 55x88 <br />% Slope of Soil Under Mound 12% <br />403 tons <br />Upslope Dike Width 9 feet <br />134 tons <br />Downslope Dike Width 36 feet <br />151 tons <br />Sideslope Dike Width 19 feet <br />30 ft. <br />60 & <br />APPROVAL <br />By Date 11/15/2019 <br />City of Orono Septic Plan Review <br />Reviewer: (( (f�..�„ See additional information sheet if checked <br />All work shall be done in full compliance <br />with all applicable septic and zoning code. <br />24910 Territorial Road • Rogers, MN 55374 <br />763-428-W9 • www.endeseptic.coni • lnfo@endeseptie.com <br />