Laserfiche WebLink
cions: = = enter data = adjust if desired Q = computer calculated - DO NOT CHANGE! <br />=bedroom Type �I Residential System <br />750 GPD design flow <br />Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />2250 Gal Septic tank (code minimum) 2250 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />1.2 GPD/ftp mound sand loading rate contour loading rate of 12 req's a min 62.5 ft. long rockbed <br />10.0 ft rockbed width 63,0 ft rockbed length <br />3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br />end feed manifold connection <br />laterals 61.0 feet long 21.0 perfs / lateral 63 perfs total <br />(1 /2 a pert means the first perf starts at the middle feed manifold) <br />7/32 inch perfs at =feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size Et spacing, ft pipe size on line 12, max perfs/lateral = 30 line #8 must be less > OK <br />io) 4.0 doses per day ( 4 minimum) <br />n) F 188 lallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />]3) 65 feet of 2.0 inch supply line leads to =gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14) 199 gallons TOTAL pump out volume (treatment + drainback) <br />ts) 17feet vertical lift from pump to mound laterals, leads to a: <br />I6) F36�GPM C 25 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17) 750 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br />leads to a <br />os) 7.8 inch swing on Demand float, or timed dosing of5.5 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow) 9 hrs OFF test and adjust as necessary) <br />i9)12 inches from bottom of tank to "Pump OFF" float <br />ao) 20 inches from bottom of tank to "Pump ON" float, or 12 inches to "Timer ON" float if time dosed <br />21) 23 inches from bottom of tank to "Hi Level" float, or 33 inches to "Hi Level' float if time dosed <br />22) 714 gallons reserve capacity (after High Level Alarm is activated) <br />0.45 Jgpd/ft2 Absorption area Soil Loading Rate, which gives a mound ratio of2.7 (minimum) <br />(this must match the soil boring log) desired mound ratio 2.7 <br />=percent site slope (0-20% range) =(% downslope site slope, if different than upslope) <br />12 inches, or 1.0 ft. to Redox or other limiting condition (need at least 12" to be a Type 1) <br />Treatment zone contains=inches of 0% soil credit, and =inches of 50% soil credit. Giving a: <br />24 Jinch, or =ft. Sand Lift Mound CRITICAL FOR FUTURE CERTIFICATIONSI H <br />27.0 ft.Total ABSORPTION width (with sand beyond rockbed as follows:) <br />+0.0 ft. up slope and sideslope <br />