Laserfiche WebLink
Replacing Rock bed as originally designed <br />DESIGN FOR AN SUBSURFACE SEWAGE TREATMENT <br />SYSTEM (SSTS) <br />PREPARED BY: <br />11/06/2018 CHIP'S SEPTIC SERVICE LLC. <br />REVIEWED FOR CODE Pernel "Chip" Hentges ORONO Copy <br />COMPLIANCE CITY OF ORONO 16762 Babcock Ave. <br />4 /� Lester Prairie, MN 55354 <br />G' /rte 952-200-3176 <br />Minnesota Pollution Control Agency Individual Sewage <br />Treatment System License No. 2064 <br />Fo - <br />Joe Falp- <br />Location of proposed septic system site: ORONO COPy <br />2650 Fox Street <br />Oi,0,40 CQrY Orono, MN 55391 <br />This site will be designed for Above Grade Mound System <br />The site must remain protected until construction begins. <br />(This is the responsibility of the owner and or General Contractor) <br />This site evaluation was completed on August 15, 2010. It is for a type one dwelling <br />with an estimated flow of 750 gallons per day. Soils information indicated a seasonal <br />water table at 14 inches. A Mound System will be required to meet the 3 foot separation <br />from the seasonal high watertable as required by MPCA Agency Rules and Standards, <br />Chapter 7080,81. <br />The Mound System design area is 51 feet wide with a length of 87 feet. Pin Flags and <br />lath have marked the location of the soil borings, plus the boundary of the system. <br />The proposed system will require (2) 1250 -gallon septic tanks, and (1) 1500 gallon <br />dosing tank. The existing tank will need to be pumped and destroyed at the time of <br />installation. The pump will need to be sized to deliver 34 gallons per minute with a lift of <br />18 feet of total head. An effluent filter must be installed in the second tank with an alarm <br />system. The filter must be checked and cleaned on a routine basis — normal use will <br />require the filter to be rinsed off twice a year (spring and fall). This is the�responsibili <br />of the systems owner. CITY OF - NO <br />SEIMC PlEitMU 9LM RE BW <br />WSPECTOA <br />��►t�ys�� DATE - -1 PERMIT NO.„�.�., <br />APiMIOVED AS stSwTTED <br />rr <br />�s <br />=8EDR00"� ANM' Ii+Irr EASE IN APPROVED WrTH CORRECT10n AS NUM <br />Of BEDROOMS WAUDATES ThisRc�y NOT as <br />ED infortiECT . All <br />work <br />the <br />�4 7'feae wmtneuu sra for your lniormsaiow. All wont altall be dosM <br />In to aoasplianea with all appllcabte septic and zoning code. <br />Requirwmcnts Including items not specifically notal intiis FIT"(kE6! THIS PLAN SET Ohl SITE AT ALL TIMES <br />