Laserfiche WebLink
INSPECTOR CHECKLIST - mound <br />/65 Lakeview Parkway <br />WE,I.L setbacks: 20' to pressure tested sewer line (5 psi for 15 min) <br />50' to everything 100' to dispersal area with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10" prop line, Metes Ft bounds: out of road easement, or outer ditch. <br />],AIE / BLUFF setback: 20' for bluff, Lakes: GD —, RD _, NE Protected wetland <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure st 10' to bed,tank Et sewer line. (else sewer line > 12" below) <br />ElSewer line fx baffle connection (no 90's, 3' between 45's, slope min 1" in 8', max 2" in 8') <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />F1Septic tank and risers (water tight, insulated, proper depth, existing verified by pumping) <br />mfg 2250 gallons none <br />Riser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent filter Et alarm <br />Dose tank risers and piping (water tight, insulated, proper depth, drainback) <br />mfg 1300 gallons <br />El dose pump 36 gpm 27 head VERIFY PUMP CURVE 5.7 min ON 9 hr OFF <br />float setting drop 8.0 inches at 25.5 gpi "DESIGNED" 5.0 inches approx float tether length <br />204.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />Cam lock reachable from grade - 30" max. J -hook weep hole. Supply line access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 118"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections <br />flow measurement: CT, ETM, time dosed, home water meter <br />mound absorption area rough up <br />mound rock dimensions 10.0 X 63.0 <br />Sand lift depth 14 inches. (Jar test : 2" sand leaves < 1/8" silt after 30 min) <br />❑ Absorption Sand beyond rock 0.0 upslope 17.0 downslope <br />ElBermed topsoil beyond rockbed 9 upslope 13 sideslope 27 downslope <br />cover depth of 12-18"+ VERIFY <br />3 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe Et fittings) <br />3.0 ft lateral spacing <br />H7/32 inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system - if necessary �Re-use existing tank certification <br />monitoring plan and type <br />well abandonment form • if necessary <br />