05-01-2018 Septic Design
Orono
>
Property Files
>
Street Address
>
L
>
Lakeview Parkway
>
465 Lakeview Parkway - 06-117-23-32-0005
>
Septic
>
05-01-2018 Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:26:37 PM
Creation date
9/28/2021 3:54:20 PM
Metadata
Fields
Template:
x Address Old
House Number
465
Street Name
Lakeview
Street Type
Parkway
Address
465 Lakeview Pkwy
Document Type
Septic
PIN
0611723320005
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br />WVHUV.SACSfI[:.iPCnurCe cnm (%iore 1 r ON <br />Property Owner-, Norton Homes <br />Site Address: 465 Lakeview Parkway <br />Comments: <br />Date: 5/1/2018 <br />PID: 0611723320005 <br />instructions: = = enter data = adjust if desired = = computer calculated - DO NOT CHANGE? <br />ibedroom Type Residential System <br />�r 45p GPD design flow <br />3) Yes Garbage disposal or pumped to septic 50% larger tank with multiple comp/tanks <br />47 1500 Gal Septic tank (code minimum) 1500 Gal Septic tank (design size / LUG req'd) <br />Tank options: none <br />1.2 GPD/ftz mound sand loading rate contour loading rate of 32 req's a min 38 ft. long rockbed <br />r; 10.0 ft rockbed width 38.D ft rockbed length <br />7) 3.0 ft lateral spacing 3.0 ft perforation spacing, (maximum of 3 for both) <br />end feed manifold connection <br />8) Laterals 36.0 feet long 13.0 perfs / lateral 39 perfs total <br />(1 /2 a pert means the first perf starts at the middle feed manifold) <br />9) 7/32 inch perfs at feet residual head gives 0.56 gpm flow rate per perforation <br />for this perf size & spacing, tx pipe size on line 12, max perfs/lateral = 30 line #8 must be less > OK <br />10, 4.0 doses per day (4 minimum) <br />o r 113 gallons per dose (treatment volume) <br />2.00 5x <br />12) 2.00 inch diameter laterals must be used to meet "4x pipe volume" requirement <br />2.00 3x <br />13 33 feet of 2.0 inch supply line leads to F 6 gallons of drainback volume <br />(Tip: "top feed" manifold to control the drainback) <br />14, 119 gallons TOTAL pump out volume (treatment + drainback) <br />i 12 feet vertical lift from pump to mound laterals, leads to a: <br />22 GPM @ 18 feet of head, Pump requirement (note: >50gpm may require an extra 3-6' of head) <br />17, 500 gal Dose tank (code minimum) 1300 gal Dose tank (design size / LUG req'd) at 25.49 gpi <br />leads to a <br />is, 4.7 inch swing on Demand float, or timed dosing of5.4 min ON (confirm pump rate with drawdown <br />(this delivers Average flow, =70% of Peak design flow)Mhrs OFF test and adjust as necessary) <br />inches from bottom of tank to "Pump OFF" float <br />17]inches <br />inches from bottom of tank to "Pump ON" float, orP30] <br />inches to "Timer ON" float if time dosed <br />,i 20 from bottom of tank to "Hi Level" float, or inches to "Hi Level" float if time dosed <br />22) 790 gallons reserve capacity (after High Level Alarm is activated) <br />