My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
EQB & MN Rules
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
3960 Sixth Ave N - 29-118-23-33-0009
>
Land Use
>
3960 CR 6 Excel substation
>
Xcel Substation 2011-2012 - File Cabinet 1
>
EQB & MN Rules
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:26:45 PM
Creation date
9/27/2021 11:51:38 AM
Metadata
Fields
Template:
x Address Old
House Number
3960
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
3960 6th Avenue North
Document Type
Land Use
PIN
2911823330009
Supplemental fields
ProcessedPID
Updated
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
301
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orono Substation Replacement Project Noise Assessment <br /> 5.0 SUMMARY AND CONCLUSIONS <br /> Existing sound levels in the vicinity of the existing Orono Substation were monitored to provide <br /> a basis for determining a source level for the existing transformer,to provide existing ambient <br /> sound levels in the neighborhood,and serve as a basis for confirming the accuracy of noise <br /> model predictions at selected locations for the proposed Orono Substation Replacement Project. <br /> Sound levels near the proposed Orono Substation Replacement site have been predicted based <br /> upon the following four alternative transformer configurations: <br /> 1. TR#1 78 dBA <br /> 2. TR#1 75 dBA <br /> 3. TR#1 78 dBA+TR#2 68 dBA <br /> 4. TR#1 68 dBA+TR#2 68 dBA <br /> Sound levels at the nearest residences are predicted to be below the State of Minnesota Nighttime <br /> Noise Standard for residential land uses(L50 is 50 dBA),but above the existing ambient sound <br /> level. To provide a greater margin of confidence that the sound levels remain below the State <br /> Nighttime Noise Standard, sound walls close to TR#1 where a 78 dBA transformer would be <br /> installed was analyzed. The sound walls would be located south and west of the transformer <br /> where the closest residences are located. <br /> Sound level predictions with the walls in place show that sound levels will be 6 dBA or more <br /> below the Nighttime Noise Standard(L50 is 50 dBA),and within 5 dBA of the predicted existing <br /> ambient levels,except for the home immediately south of the transformer where the level may be <br /> 8 dBA above the predicted ambient level(Home 5). Increase in the wall height to 16 feet would <br /> reduce the sound level at Home 5 bringing it closer to the existing ambient. When a 68 dBA <br /> transformer is added at the TR#2 position,a 16 foot wall would be needed to maintain the level <br /> at Home 5 instead of the 14 foot wall for the 78 dBA transformer alone. <br /> y:\jobs\2011 jobs\211065\report\orono-substation-noise-assessment-011212.doc <br /> David Braslau Associates,Inc. Page 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.