My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Orono Substation Replacement
Orono
>
Property Files
>
Street Address
>
S
>
Sixth Avenue North
>
3960 Sixth Ave N - 29-118-23-33-0009
>
Land Use
>
3960 CR 6 Excel substation
>
Xcel 2011 - File Cabinet 1
>
Orono Substation Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:26:47 PM
Creation date
9/23/2021 3:38:36 PM
Metadata
Fields
Template:
x Address Old
House Number
3960
Street Name
6th
Street Type
Avenue
Street Direction
North
Address
3960 6th Avenue North
Document Type
Land Use
PIN
2911823330009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
162
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> I <br /> ILIST OF TABLES <br /> Table 1 Completeness Checklist 3 <br /> I <br /> Table 2 Estimated Project Schedule 10 <br /> Table 3 Estimated Project Cost 11 <br /> Table 4 Detailed Description of Proposed Route 13 <br /> I Table 5 Structure Design Summary 22 <br /> Table 6 Calculated Electric Fields (kV/m) for Proposed Transmission Line Design <br /> (3.28 feet above ground) 32 <br /> I Table 7 Calculated Magnetic Flux Density (milligauss) for Proposed Transmission <br /> Line Design (3.28 feet above ground) 33 <br /> Table 8 Distance to Occupied Structures 41 <br /> I <br /> Table 9 Common Noise Sources and Levels 42 <br /> Table 10 Noise Standards by Noise Area Classification 43 <br /> Table 11 Calculated Audible Noise (dBA) for Proposed Transmission Line Design <br /> I (3.28 feet above ground) 44 <br /> Table 12 Population and Economic Characteristics of the Project Location 47 <br /> Table 13 Wetlands within the Proposed Route 56 <br /> I <br /> Table 14 Rare and Unique Resources Near the Proposed Project 61 <br /> Table 15 Potential Required Permits 69 <br /> LIST OF FIGURES <br /> I <br /> Figure 1 Project Location 2 <br /> Figure 2 Proposed Route 7 <br /> I <br /> Figure 3 <br /> Figure 4 Photo of Typical 115 kV Double Circuit Steel Davit Arm Structure 21 <br /> Photo of Typical 115 kV Single Circuit Steel Davit Arm Structure 21 <br /> Figure 5 Photo of Typical 115 kV Single Circuit Steel Braced Post Structure 22 <br /> I Figure 6 Typical Dimensions and Right-of-Way Requirements For Double Circuit <br /> 115/115 kV Davit Arm Structure 24 <br /> Figure 7 Typical Dimensions and Right-of-Way Requirements for Single Circuit 115 <br /> I kV Davit Arm Structure 25 <br /> Figure 8 Typical Dimensions and Right-of-Way Requirements for Single Circuit 115 <br /> kV Braced Post Structure 26 <br /> ILIST OF APPENDICES <br /> Appendix A Applicant's Notice Letter to Commission of Intent to Use Alternative Permitting <br /> IProcess <br /> Appendix B Maps <br /> I Figure B-1 General Vicinity Map <br /> Figure B-2 Proposed Project and Route Location <br /> Figure B-3 Land Use Land Cover <br /> I Figure B-4 Zoning <br /> Figure B-5 Property Parcels <br /> Figure B-6 Wetlands and Waterbodies <br /> I Figure B-7 Parks and Recreational Areas <br /> Figure B-8 Locations of Known Rare and Unique Resources <br /> I Orono Project June,2011 <br /> MPUC Docket No.E002/TL-11-223 iv <br />
The URL can be used to link to this page
Your browser does not support the video tag.