Laserfiche WebLink
� o� <br /> o :., o <br /> �4��::w- c i�Y�� oRoNo <br /> � �r�'�;��,,�' .'� <br /> � ?k�� �;. ��, Municipal Offices <br /> �� ��� � .�,�G Street Address: °ISot-a4 9-�6o O <br /> .f, , Mailing Address: <br /> `�$�Hp'g' 2750 Kelley Parkway P.O. Box &6 <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> To Current Owner: Address: ���� �ig I ��� �A �� � c� <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatrnent system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): � <br /> 1 "CODE SYSTEM"An ISTS which meets all the location,�sign and construction standards of the cutrent Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISTS which does not meet all the location,design and wnstruction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or eazlier,and <br /> which is not failing or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited LSTS;an IST'S located within a�signated 100.year flood plain,any ISTS which may <br /> or may not�et all the location,design,or consttuction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISTS with less than three feet of unsaturate3 soil or sand beiween the distrtbution�vice and the limiting soil characteris6cs. <br /> TANK CONDTI'ION(5-7): � <br /> Tank inspection indica.tes: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pum.ped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumned throu¢h manhole and not throush white inspection niaes. This allows for the proper <br /> cleanine Keep water softner and iron ftlter discharee out of seatic svstem to prolone life of drainfield. Ask pumuer to test <br /> alarm float to verifv alarm is siill worlune in vour house. The alarm warns owner that septa�e is about to backup into basement <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tankc have not been pumped out within the last three years,they should be pumped out now. <br /> DRAINFIELD CONDTTION(8-10):� � <br /> 8 Drainfield is dry,no surfa.cing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is sa.t�u�ated and visibly discharging untreated efIIuent to the surface. Contact the City Inspector <br /> immediaxely.Repairs must be completed within 90 days. <br /> COMMENTS: <br /> � <br /> � - I �� - O� <br /> Date of Inspection Sepric System Inspector <br /> Note: 7n the event that this inspection report is used to satisfy t�he requirements for a mortgage or otha hznsfer of properiy,be advised that this report do� <br /> not g�arantee or certify that an existing system w�71 continue to function properly, but is merely an opinion of the adequacy of the system under ciurent <br /> condidons based on the available information. <br />