Laserfiche WebLink
Task 53839 <br />Date Called in 06/03/21 <br />Date Scheduled 06/08/21 @ 10:00+ <br />City Of Orono <br />Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form <br />Property Address: 285 Leaf Street <br />PID: <br />EXPIR <br />Owner Information <br />Name: <br />John Brunello <br />Mailing Address: <br />refrom <br />Pro e <br />Property) <br />10 Avenida Aldea, Santa Fe, New Mexico, 87507 <br />Phone: <br />612-221-4408 1 Email: I jbrunello@yahoo.com <br />Inspector Information <br />Name: <br />Company/ Organization License number: <br />Phone: Email: <br />Inspection <br />System <br />Standard <br />Pass <br />Fail <br />Roof Drains <br />Roof drains and leaders Roof drains should not be connected to the sanitary <br />sewer but should discharge to the ground outside of a building. If the roof <br />drains are connected to the sanitary sewer, disconnect them, plug any open <br />connections to the sanitary sewer using a non -shrink permanent material, and <br />redirect the roof drains onto the ground outside the building. <br />Foundation <br />Foundation drains are underground pipes that collect storm water from <br />Drains <br />around the base of a building and into a sump basket, where it is then <br />pumped outside of the building. Foundation drains should not be connected <br />to the sanitary sewer. <br />Sump Pumps <br />Sump pumps are designed to capture surface or ground water that enters <br />basements or crawl spaces and pump it away from the house. The basic. sump <br />system includes drain tile, a su p -pit, a sump pump, a float or switch, and a <br />drain line. Sump pumps s Id not be connected to the sanitary sewer. <br />Sewer Service <br />Sanitary Sewer inflow & Infiltration (1/I) Compliance inspection Sanitary <br />Line <br />Sewer Lines. All sanitary sewer lines serving Property, from the house to the <br />main line, shall be in a safe and functional condition and shall be free from all <br />leaks, failures including but not limited to partially collapsed sections or tree <br />root intrusion. The sanitary sewer lines shall meet the City Code standards and <br />specifications. (Details on back of this sheet) <br />Notes: <br />Toilet Removed <br />o YesN0 <br />For Inspection: <br />/ <br />1 <br />Inspectors Signature: &LINN Date: <br />Owners Signature: Date: <br />City Review <br />Compliant ❑ Corrective Action Required <br />Certificate of Compliance Expires:LPA-A031&ctive Action Due by: <br />Date: Signature: <br />U- % - at Name: X1 A V% 0 1 1 .1..n <br />