My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic design/info
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2290 Abingdon Way - 03-117-23-23-0010
>
Septic
>
Septic design/info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:22 PM
Creation date
7/27/2015 1:29:44 PM
Metadata
Fields
Template:
x Address Old
House Number
2290
Street Name
Abingdon
Street Type
Way
Address
2290 Abingdon Way
Document Type
Septic
PIN
0311723230010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� INSPECTOR CHECKLIST - mound <br /> 229Q Abi�don Way,Orono <br /> a �vF.i,L se�badrs: 20'to preuure tested sewer line (5 psi for 15 min) <br /> • 54'to everythtng 1Dd'W dispersal area with shallow welt <br /> PROPERTY LII�ES aetback: 10'to everythtng <br /> Road setbacic: outer dttch,or 33'from center of twxnship road,or 65'from center of cnty road <br /> LAKE/BLUFF �back: 20'for bluff. l.akes:GD_.,ItD�,NE_. Protected wetland_ <br /> Bu�ding�baatcs: 10'for everything, 20'for disp2rsal area. <br /> WATER L[NE under pressure e�10'to bed,tank�sewer li�.(else�wer Une>1 Z"below) <br /> � Sewer line fe baffle tannectfon (no�'s, 3'between 45s, slope min 1'9n 8',max 2"in B') <br /> (nc depth req's, clean out every 100', Sch 40 D26b5 or F�91) <br /> � Septfc taMt and risers (water ttght,iinulated,proper depth,exlsdng veHHe�l by pumpir►g) <br /> mfg �QO gaUons rrone <br /> Riser ower outlet, rtser over tntet, 6"+inspectlon pipe over any remaining baffles. <br /> Ido etftuent Htter&alarm <br /> Dose tank risers and piping (water tlght,ir►wlated,proper depth,dralnback} <br /> mfg 1250 galtau <br /> � dose pump 47 gpm 18 head VERIFY PUMp tURVE 4.1 min ON 9 hr OFF <br /> � float setting drop 16.1 inches <br /> LABEL pump requirements and drawdown on riser or panel <br /> Cam lock, areep hole, suppty line access (no hard�,pipes reachabie fram grade-36� <br /> �PP�Y P�stoped 1/8"+� sW�ported by schAB sleeve, and bwied 6'+. <br /> splice box/control panel/electrical connectfons <br /> flow measurement:CT,ETAA,time dosed.Frome evater meter <br /> 8 mound rock dimensiais 10 X 52.5 <br /> 5and Ufk depth i2 irrches. (Jar test:2"sand leaves<1/8'silt after 30 min) <br /> � Absorption Sand beyond r�k 0.0 upslope 77.0 dawnslope <br /> � Bermed topsoil beyond rockbed 9 ups[ope 15 sideslope 22 downslope <br /> � caver depth of 12-18"+ YERIFI' <br /> 3 (aterais (1•Y from edge of rotk} <br /> 2.00 inch pipe size <br /> 3.0 ft lateral spacing <br /> 8 1/4' inch perForatior�s (s�l�er is ok) <br /> 3.0 ft peAoration sPBcing <br /> Air 9nlet at end of laterats, and at top feed manifold. VERIFY <br /> clean outs (rro hard�'s) <br /> 4"ir�spection pipe to hottom of rock,anchored YERIFY <br /> Abandon e�ddsting system if�seces�ry �Re-�e exfstEnB tank certif9catian <br /> manftori�plan and type • <br /> well abandaiment form if necessary <br />
The URL can be used to link to this page
Your browser does not support the video tag.