My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
re: septic system
Orono
>
Property Files
>
Street Address
>
A
>
Abingdon Way
>
2285 Abingdon Way - 03-117-23-23-0007
>
Septic
>
re: septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:00 PM
Creation date
7/27/2015 1:19:31 PM
Metadata
Fields
Template:
x Address Old
House Number
2285
Street Name
Abingdon
Street Type
Way
Address
2285 Abingdon Way
Document Type
Septic
PIN
0311723230007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� o� <br /> �;� 0�1��. O � <br /> ��::�..:� CITY of O]1�O11T0 <br /> I.� 's�`����? � <br /> '� !`�-;��``.�t';�` `ti� Municipal Offices ' <br /> � !r.'�'� ��^:t Y�3' ��7 . <br /> �9�`;fia';:O4�i Street Address: Ma1Ung Addreu: <br /> . Eg�1 �� 2750 Kelley Parkway P.O. Box 66 � � <br /> Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> Owner: �fi 2 L��c• �a� e�/ Address: a��� �b:r� d�1� W�,�• <br /> Cits�Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site se«•age treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-31: I <br /> � "CODE SYSTEM" An ISTS which meets aI!the location,design and construction standards ofthe cuirent prono Municipal Code. . <br /> 2 "CONIPLIANT SYSTEM" An ISTS which does not meet all the Iocation,design and construction standards oftha cutrent Orono Municipal <br /> Code but does meet the threa foot separation requirement,aad which is not failing or an immiaent threat to public health or safety. <br /> 3 "NON-COI�PLIANT SYSTEM" A prohibited ISTS;an ISTS located within a designated 100-year flood plain,any ISTS wlrich may <br /> .or may not meet all the location,desigx�or const�uction standards of the cuaeat Orono Municipa!Code and which is failing for any reason;and <br /> any ISTS with less than three feet of unsatunted soil or sand between the distribution device and the limiting soil characteristics. <br /> � TANK CONDITION(�-10): G <br /> Tank inspection indicates: • <br /> � Pumpout not needed at this time. <br /> � Tanl:must be pumped out this year (city code requires tarilcs to be pumpzd out every 3 years. Tank was last pumped I C'��`1—�7 ), <br /> 7 Solids accumulation in tanks is at a critical a critical lar•el. Tanks shou(d be pumped out as soon as possible. <br /> 3 Systecn is discharging to tha surFace. Tanks must bz pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspntion risecs missing-tanks could not bz inspecttd Inspection risers(4"dia pipe)must be installed in each tank at ne�tt pumpout If tanks <br /> ha�•e not bern pumped out«ithin the last three years,they should be pumped out now. <br /> 10 Inspaction pipz is located directly over tank ba81e(does not give accurate measurement of solids accumulation). If tanks have not been pumped <br /> out within tha last thrze years,they should be pumped out now. <br /> DRAI�TFIELD CONDITION(11-141: �� <br /> , • � Drainfield is dry,no surfacing evidmt . . , <br /> 12 Some e�Ydence of surfaciiig,not critical yet � � ' , <br /> 13 Draintield is saturatzd and visibly discharging untreated eSluent to the surface. ContaM the City Inspector immediately.Repaiis mnst be <br /> completed wi[hin 90 days. <br /> 1� Draintir(d estant and conditioa unknown <br /> CON1v1ENTS: C�`��S C-�'.¢p;r.c�S ;•� � ��oP Q L�X25 <br /> `��^°��_v l �� I I���^��-- <br /> Date of Inspection ' Septic System Iaspeetor ' <br /> Aiotr. Ia the event that this inspectioa repod is used to satisfy the requirements for a mortgage or other transfet of property,be advised that this reprnt does not guarantea. <br /> or certify that an e.cisting systzm will continue to function pmperly,but is merely an opinion of the adequacy of the system uader cutreat conditions based on the available <br /> informatioa <br />
The URL can be used to link to this page
Your browser does not support the video tag.