Laserfiche WebLink
POOL KIT MATEAIAL LIST � <br /> GRECIAN � Y <br /> CORNER 45° � Y <br /> FILLER W � a� <br /> 18 x45 � w � �+ � a � � <br /> J Z W J J J J J Z J LL ¢ Y U b � <br /> LAZY EL � a � aaaaaaza � J � � o � � <br /> Nawzaaaaa - a � �y OUt'"' -� <br /> 1�` pz � °C zzzZzaz W z Zm = w <br /> '+�/� LAZY EL CORNER � � — � ¢ N a N c� <br /> IYPICAL DETAIL (TYP.) gY � ggggg °' g � � ow � oaWn}i <br /> GRECIANCORNER ama� aaan. a� aLL W ¢ � Q ¢ ZQ <br /> SIZE ao m oo m u� v io i�' Q Lt � C7 Z Q N � J <br /> 16x45 7 2 2 4 I 2 2 144 4 I I I 1 I I <br /> 18 x 45 w/stairs 5 2 2 4 2 I I 2 14 4 4 I I I 1 I I <br /> r- 31�6-3/4" -� <br /> NOTES <br /> 8 8 6 6 I-I/2 <br /> �_��2 1.POOL IS DESIGNED FOR USE BELOW GRADE AND <br /> ONLY IN AREAS WHERE THE GROUND WATER <br /> , p I TABLE IS A MIN.OF 4'8'BELOW THE PROPOSED <br /> g 4 O � , „ 6 ' FINISHED GRADE <br /> H O-3/4-►� 2 BACKFILL WITH CLEAN EARTH.FREE OF ROOTS <br /> S I / AND DEBRIS.DO NOT ALLOW THE HEIGHT OF <br /> � � u BACKFILL TO EXCEED THE HEIGHT OF THE <br /> 1 " 19 6-3/4 WATER IN THE POOL BY MORE THAN 8',NOR <br /> I s � „ WATER TO DCCEED BACKFILL BY MORE THAN 6". <br /> 81 18,�u 26 9 3. POUR 2500 P.S.I.CONCRETE FOOTINO AROUND <br /> LIGHT I 19 6-I/2 <br /> � n ENTIRE PERlMEfER,MIN.8'DEEP. <br /> PANEL 2 10 O � 4.3'WIDE CONCRETE DECK IS TO BE POURED AT <br /> OPTION ( 6 AWAY FROM�THE POOL D A SLOPE OF 1/4"TO 1' <br /> � LEFT EL 5.ALL INSIDE POOL DIMENSIONS AHE TO BE <br /> S I FINISHED DIMENSIONS. <br /> 6.FINISHED BOTTOM IS TO BE 2'MIN.OF <br /> 5 4�Op 8"��Z I � � SUITABLE MATERIAL OR UNDISTUflBED EARTH. <br /> " 21 10-5/8 7.A SAFETY UNE,WITH BUOYS,IS TO BE PER- <br /> MANENTLY ATTACHED 1'0"TO THE SHALLOW <br /> SEE LAZY EL 8 5 SIDE OF THE POINT OF FIflST SLOPE CHANGE. <br /> S 8 8 CORNER DETAIL 8.COPINCi:COPING LENGTHS ARE APPROXIMATE <br /> CUTS MAY BE NEEDED ON STRAIGHT SECTIONS <br /> 24�Z_��2^- _ 2 FOR PROPER FIT.RADIUS CORNERS ARE 2'x 2: <br /> \8 9.CONSTRUCTION DAAWINGS:THESE DRAWINGS <br /> 8� AND NOTES ARE FOR ILLUSTRATIVE PURPOSES <br /> STEP ONLY.DIFFERENT MEfHODS AND PRECAUTIONS <br /> MAY BE DICTATED BY VARIOUS GROUND CONOI- <br /> �2�2-�/2° 8 UNIT TIONS.THIS IS TO BE DETERMINED BY AND IS <br /> � THE RESPONSI8IUTY OF THE CONTRACTOR, <br /> WHO IS NOT AN AGENT OF THE MANUFACTUHER <br /> 5 OF THE ROYAL POOL <br /> 70.INSTALLATION IS TO BE DONE IN ACCOiiDANCE <br /> 45�S�� BUI DWG CODESAS WELL AS N PJASUG- <br /> GESTED STANDARDS. <br /> 12 12 4 <br /> � 3�4° NSPI DIVING POOL <br /> 4 -RADIUS CORNERS �2 REFER TO CURNENT N.S.P.I.PUBUCATIONS <br /> 7�10" 8 � -GRECIAN CORNER T�DN NG E�UI MPENT A�LLOWED.OF <br /> I -EL CORNER 4 FOR MORE INFORMATION CONSULT <br /> � �� 6 7-12� SECTI ONS NATIONAL SPA&POOL INSTITUTE <br /> ��Z MINIMUM � 2111 EISENHOWERAVENUE <br /> PREPARED BOTTOM Z-B SECTIONS ALEXANDRIA,VA 22314 <br /> TEL(70�838-0083 <br /> 12 8 8 TITLE <br /> �«4�Ou+�-6�0�� •�. 13�6"—� COPING LAYOUT g 18 x 45 LAZY EL (LEFT EL SHOWN) <br /> 6 DATE SCALE DRAWN BY �AJ_C.C. <br /> ( /I /$6 NONE APPROVED BY <br />