LEGEND Ii _ -_ ❑ <br /> UTILITY NOTES: } I i 0 20 40 <br /> -w-1.-PROPOSED STORMSEWER C SILT FENCE&BIO LOG--- <br /> 5'APART Feet $ <br /> ---PROPERTY LINE 1. REFER TO COVER SHEET FOR GENERAL NOTES AND UTILITY NOTES. i <br /> -RAY-RIGHT OF WAY 2. STORMTECH INSTALLATION IS SHOWN HERE IN PLAN VIEW FOR LOCATION AND CONNECTION TO D N. <br /> \• o <br /> ------GAS LINE STORMWATER MANHOLES AND CATCHBASINS.OWNER WILL STAKE EASEMENTS. (- 1 I i I <br /> -.-.-UNDERGROUND ELECTRIC 3. SEE STORMTECH SUPPLEMENTAL INFORMATION FOR CB AND MH SHOP DRAWINGS,MANIFOLD AND I •y <br /> -a � <br /> -a-OVERHEAD ELECTRIC CHAMBER CONFIGURATION. -I <br /> 4. ALL STORM DRAIN INLETS MUST BE PROTECTED BY BMPS DURING CONSTRUCTION UNTIL I I I I ` • �,-,--._�- ~ I s <br /> - -UNDERGROUND TELECOM STABILIZATION IS COMPLETE. Ai ( ' � I I '' <br /> EXISTING STORMSEWER 5. PIPE OUTLETS MUST HAVE RIPRAP IN PLACE WITHIN 24 HOURS OF OR PRIOR TO CONNECTION TO THE 5 <br /> EXISTING 6"DRAINTILE(APPROX) STORMTECH SYSTEM. <br /> -I -i -WATERMAIN / <br /> .-.-SANITARYY SEWER GRADING NOTES: T� I b � • <br /> - <br /> EASEMENT J -.-- --1 , ( I <br /> EXISTING MAJOR CONTOUR ( ; I 4 I I Er <br /> 1. PROPOSED SPOT ELEVATIONS AND CONTOURS ARE TOP OF GRADE,PAVEMENT OR GUTTERLINE, <br /> EXISTING MINOR CONTOUR j <br /> UNLESS OTHERWISE SPECIFIED. i � v � � j <br /> PROPOSED CONTOUR(2-FT) 2. SEE DRAWING NO.2 FOR EROSION AND SEDIMENT CONTROL PLANS. --d 1I \ 1 I 2 <br /> PROPOSED CONTOUR(1-FT) 3. CONTRACTOR WILL COMPLETE GRADING OF DISTURBED AREAS WITH A MINIMUM OF SIX(6)INCHES OF $ \\ ■ • <br /> -..-•-SILT FENCE TOPSOIL,REPLACED FROM ON SITE STOCKPILES OF TOPSOIL OR WITH TOPSOIL BORROW.TOPSOIL E (- ( \ \ I TAP BASIN <br /> -.-n-BIO LOG BORROW WILL CONTAIN 3%TO 10%ORGANICS.DISTURBED AREAS WILL BE REVEGETATED WITH SOD, f I I INV 6=941.0 <br /> >•�' t:Co'�;;,:TURF REINFORCEMENT MAT(=760 FT2) BY OTHERS. $ I ; j I INV.W=936.3 <br /> e� FLOW PATH I I,. dl \/ <br /> - DRAINAGE ARROW i' / ` I 1 <br /> INV.936.0 <br /> 0.1 <br /> HYDRANT GATE VALVE Cl., INV,929.8 // <br /> 11J r <br /> WATER BOX I- NV.942.6 <br /> _t•10 NO INV.ON FES 1 12'CMP <br /> INV.929.7 I 6 I , I <br /> NOTE:UTILITY 5110WN BUSED DN APPROXIMATE LOCATION I 1 <br /> FROM IANOOWNER,CONTRACTOR'S RESPONSIBILITY TO A I I / ( I <br /> LOCATE UTILITIES PRIOR TO CONSTRUCTION. J <br /> III l <br /> ; / / � I <br /> NOTE: A PORTION OF THE ADJOINING $ 1 \ <br /> HOUSE LOCATION TAKEN FROM A SURVEY II i \\ 1. <br /> G <br /> BY CARDARELLE DATED 3-18-18. <br /> ,: • PER OWNER, <br /> ///jjj • ) UNDERGROUND <br /> t -- • IMMINIMIIIINED <br /> TELEPHONE CAN <br /> �� d : ,:� �,�ML 8.....ABANDONED <br /> I I I . ' 4/ m FOR RIPRAP AT ,. <br /> // ��CULVERT END ._,.. <br /> I <br /> / ? / 78 LF 8'SINGLE WALL <br /> I I <br /> CORRUGATED HDPE STORM ^^,, 11 <br /> ...„.. <br /> 1 - DRAINTILE FOR SAND FILTER V R` Z rn <br /> ♦ /R' ( LAYER(SEE DRAWING NO.02) T - - ^, j O V <br /> ♦\ $ / 41:' 90>BEND . / ctiV v L Z <br /> ` "I I I-:,4, •--- . ...�� r �a.i FOR INSULATION I ^�>� Lif Ui C <br /> \ ♦ SECURE BIOLOG AROUND /* FES INV.937.9 -I / ' / ` a f+l tD 3 <br /> i ��� DRAINAGE&UTILITY <br /> DOMED INLET GRATE / FES_____. <br /> UNTIL SITE 15 STABILIZED I �� M_a�� . r/'F EASEMENTS I� 1� y <br /> CB-02 S -�R , - C_ <br /> \ TOP=943.00(INLET ELEV.) 1 : f r4T_ 1 '� , _ �I • E <br /> • .\ ` BOT=9((IN) (/� / M-�' ' a w a 1111 <br /> INV.5=940.50(IN) SIT )111#11/* <br /> ♦ INV.E=940.10 OUT) � I /'f 1 �"-l: TNH=(949.73) <br /> ♦ INCLUDES DOMED INLET GRATE j� - - .!<� <br /> \ • <br /> . l✓�' - ' - --' FOR ROCK 1 - \`` _� CONTRACTOR TO VERIFY IIIIIIIMIIIIIIIM <br /> LOCATION OF\ ---"---" ATER <br /> '�^' \♦ ` ..�,R'r�'- ♦ ♦ - �� OVERFLOW 6,.UNC N ��� 1,_ • FORCEMAIN PRIOR TO <br /> r� <br /> �/ �' // -� •�'�jf/�-s t{ AI----------'-'-----'-' <br /> ''- INSTALLING STORMTECH O W o <br /> .--%!'.""'iiii� s , • ! "12'HDPE/ lio ® SYSTEM ADDRESS ANY W <br /> ifi2 <br /> v -'' ----- ' CONFLICTS IN ADVANCE. <br /> TNH:946.91 -' ' �jr2^N125T0 .- ` UTILITY EASEMENT W g 5 w w x a <br /> l ) ' Itch,57 LF . _. 70P.945.9 o n o¢ ❑ a <br /> . - - p -1-.`.-..�J : ll <br /> j wi' i. BOT=936.9 PER DOC.NO.1024262 1 <br /> ` - �,;.+�'..'�••�' `y:�1 i�� @ � .� '� .• INV.W.939.55(1N) <br /> [NV.NW-939.0 IN UNDERDRAIN <br /> ry� -... �,r `/ INV.N=938.9(OUT) 1BETWEEN STORMTECH0'MINIMUM BED <br /> . „^"'.:-..-- ' -.. �' , &WATER LINE STORMTECH o 4"OR1FiCE-939.2 <br /> -' � Y7 M WEIR-941,5 <br /> ''�_ INSULATE IF £ �� / ' ./// I <br /> ..,, ^,,,f• - / <br /> m CLEARANCE IS n ' MH-05 I <br /> • R LESS THAN 12" O ' m FOR STORMTECH TOP=947.8 0 <br /> y __ MH-03 WI CROSS SECTION BOT=937,5 <br /> .� 'r TOP=946.00 LIMITS OF BED INV.W=939.5(IN) Z <br /> z ./' /BOT=937.50 94'X22 I 0 W <br /> ' � ' INV.W=939.60(IN) / 0 Ill <br /> FIVE 6'DRAIN TILE LINES , ///yL INV.E-939,0(OUT) //_ C <br /> e IN SINGLE TRENCH,END ..'h ' I /�INV 5-940.88(OUT) STORMTECH BED 1 FOOT OFFSET FROM (,(n <br /> �I A <br /> ♦ POINT IS APPROXIMATE ----;-r--u4 / //- UTILITY EASEMENT NO.1024262 CC} <br /> i ♦♦ / 15 LF 8'612 STOR ' / \ .- J/ I. (/� <br /> / 10'MINIMUM CLEARANCE _ .- tt I Il-I <br /> 3 ' BETWEEN STORMTECH BED _ - 0 lY <br /> 1-0' <br /> ♦♦ v1 f\�,/I T -1 /,.' &SANITARY SERVICE / <br /> ` u V I I �/ '""dam-f =Q <br /> • <br /> I '' it <br /> / } <br /> - \ DRIVEWA 1 Y <br /> ce <br /> Y ` I I I /YYY / J U <br /> 6 �' 16 MANIFOLD FIVE 6"DRAIN TILE / ♦ I' , ,J' i'�J +" I w Z Q - <br /> PR INTO ONE 8"AND TRANSITION ♦ .�� }1- /// �./� a w <br /> \ ` • TO 8"N12 PIPE TO MH-01 m FOR TP.ENCH ♦ �(/ - a <br /> .' ` ' ' �. �y BACKFILL(TYP) (/ri <br /> a. <br /> ea <br /> ll <br /> PROPOSED DRAINAGE 40. E XI S iev 0 MH-01 // � /// <br /> AREA 216,336 FTS - (COLLECTS ALL ROOF DRAIN TILE) <br /> _� `4 _/ TOP=950.0 // #i ,,YN <br /> H0UW=941.1MIN(oA ,/ <br /> 12"ADD-A-BRANCH INV. MIN UT)// ' , I O <br /> 8"INV.N=941.0(OUT) L <br /> O a O <br /> //// / I' ❑o <br /> PROPOSED <br /> DRIVEWAY / �/ /� 0 o <br /> / Z <br /> W LU <br /> LU <br /> �'/� 11 I / ,9/ '' o W <br /> To LIT O <br /> Z O co c DRAINAGE&UTILITY EASEMENTS �- <br /> °$ / II / o a CO <br /> 8s / EXISTING C ! a <br />