My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Temp COO - 2016
Orono
>
Property Files
>
Street Address
>
B
>
Bracketts Point Road
>
1220 Bracketts Point Road - PID: 11-117-23-32-0018
>
Misc
>
Temp COO - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:29:46 PM
Creation date
5/29/2020 12:42:06 PM
Metadata
Fields
Template:
x Address Old
House Number
1220
Street Name
Bracketts Point
Street Type
Road
Address
1220 Bracketts Point Road
Document Type
Misc
PIN
1111723320018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
160
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- Beam Design <br /> � RAM Concrete Beam v 14.07.01.01 Page 7/30 <br /> RAM Database: 2015-12-21 Hannaford DD 02/02/16 09:38:44 <br /> Building Code: IBC Concrete Code: ACI 318-1 l <br /> BEAM INFORMATION: EXTERIOR GRADE BEAM CONTROLLING CASE <br /> Stoiy Level Graund Floor <br /> Beam Number 71 Grid Location_ (52.12ft-24.33ft)-(52.12ft-32.62ft) <br /> Beam Line Number- 16 Span Number_ 3 <br /> Geometry <br /> Size:. _________ 5'-0" GB <br /> Depth (in) 60.00 Web Width (in) 12.00 <br /> Flange Width (in) NA Flange Thicicness(in) NA <br /> Length c-c (ft) 8.29 Clear Lenglh (ft) _ _ ._. _ __.._.__ _ 7.29 <br /> Left Support Length (in)- 12.00 Right Support Length (in) 12.00 <br /> Left Support Width (in) 12.00 Right Support Width (in) 12.00 <br /> MATERiAL PROPERTIES: <br /> Fc(ksi) 4.00 fy Longitudinal (ksi). ________. 60.00 <br /> fct(ksi) 0.00 fy Transverse (ksi) 60.00 <br /> Conc. Weight(pc�_-_-.__ 145.00 Conc. Type NWC <br /> Coilc. Modtilus (ksi) 3644.15 Reinf. Modulus(ksi) 29000.00 <br /> General Warning(s): <br /> Sectiov must be designed as a Deep Beam per ACI 318-11 for shear. Section must be designed as a Deep <br /> Beam per ACI 318-11 for flexural design. <br /> TOP LONGITUDINAL REINFORCEMENT: <br /> Start End End-Condition <br /> Set Sizc Num Depth Layer Supp. Loc. Supp. Loc. Start End <br /> (in) (ft) (ft) <br /> 4 #6 3 15.500 Upper 4 -7.208 4 6.792 Splice Splice <br /> Max. Bar Deptl�Limit(in): 57.625 Clear Bar Cover(in): Top: 1.500 Side: 1.500 <br /> BOTTOM LONGITUDINAL REINFORCEMENT: <br /> Start End End-Condition <br /> Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End <br /> (in) (ft) (ft) <br /> 3 #6 2 57.500 Lower 3 0.084 3 8.084 Splice Splice <br /> Max. Bar Depth Limit(in):- 57.625 Clear Bar Cover(in}: Bot.: 1.500 Side: 1.500 <br /> LONGITUDiNAL BAR DESIGN DETAILS: <br /> Positive Moment Negative Moment <br /> Loc. Mu eMn As req. As Mu eMn As req. As <br /> (ft) (Icip-ft) (lcip-ft) (inZ) (inz) (kip-ft) (kip-ft) (in2) (in2) <br /> 24.916 0.00 225.14 0.00 0.86 -20.72 -229.09 0.11 0.83 <br /> 25.416 0.00 225.14 0.00 0.59 -20.72 -252.85 0.11 0.65 <br />
The URL can be used to link to this page
Your browser does not support the video tag.