Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Airics Heating LLCIII 1330 Cherry Place <br /> New Prague,MN 56071 Page 8 <br /> [System 1 Summary Loads <br /> Component Area Sen Lat Sen Total <br /> Description Quan Loss Gain Gain Gain <br /> 1D-cv-o: Glazing-Double pane, operable window, clear, 393 18,818 0 15,107 15,107 <br /> vinyl frame <br /> 15A11-Ofcw-6: Wall-Basement, , framing with R-11 sill to 1392 6,914 0 284 284 <br /> floor in 2 x 4 cavity, filled core, no board insulation, <br /> plus interior finish, wood studs, 6'floor depth <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 2007 11,463 0 2,238 2,238 <br /> cavity, no board insulation, siding finish, wood studs <br /> 16CR-38: Roof/Ceiling-Under attic or knee wall, Vented 2716 5,932 0 2,754 2,754 <br /> Attic with Radiant Barrier, Dark Asphalt Shingles or <br /> Dark Metal, Tar and Gravel or Membrane, R-38 <br /> insulation <br /> 19B-Osp: Floor-Over enclosed unconditioned crawl 2160 5,912 0 985 985 <br /> space, R-4 insulation on exposed walls, sealed crawl <br /> space, passive, no floor insulation, carpet or <br /> hardwood <br /> Subtotals for structure: 49,039 0 21,368 21,368 <br /> People: 8 1,600 1,840 3,440 <br /> Equipment: 0 0 0 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 <br /> Ventilation: Winter CFM: 300, Summer CFM: 300 26,895 6,639 4,482 11,122 <br /> System 1 Load Totals: 75,934 8,239 27,690 35,930 <br /> Check Figures <br /> Supply CFM: 1,087 CFM Per Square ft.: 0.223 <br /> Square ft. of Room Area: 4,876 Square ft. Per Ton: 1,585 <br /> Volume (ft3)of Cond. Space: 39,008 Air Turnover Rate(per hour): 1.7 <br /> System Loads <br /> Total Heating Required With Outside Air: 75,934 Btuh 75.934 MBH <br /> Total Sensible Gain: 27,690 Btuh 77 ok <br /> Total Latent Gain: 8,239 Btuh 23 <br /> Total Cooling Required With Outside Air: 35,930 Btuh 2.99 Tons (Based On Sensible + Latent) <br /> 3.08 Tons (Based On 75% Sensible Capacity) <br /> Notes <br /> Calculations are based on 8th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads- <br /> C:\Program Files\Elite\Rhvacw\Projects\martinson.rhv Thursday, January 18, 2007, 3:50 PM <br />