Laserfiche WebLink
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Airics Heating LLC 1330 Cherry Place <br /> • New Prague,MN 56071 - Page 6 <br /> System 2 - - Adequate Exposure Diversity Test <br /> Test For Adequate Exposure Diversity <br /> 10,000 28.3% Diff. from Avg. <br /> 8,000— <br /> m – <br /> 6,000 <br /> a) <br /> a 4,000 <br /> cn <br /> ca <br /> C <br /> 2,000 <br /> 0 I I 1 f 1 1 1 I -I <br /> 8am 9am 10am 11 am 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm <br /> Average Glass Load 1.3 x Average / Hourly Glass Load <br /> Over 12 Hours <br /> AED Calculation Summary <br /> --- SYSTEM HAS ADEQUATE EXPOSURE DIVERSITY. --- <br /> System is on N, E, S, W rosette. <br /> Peak load exceeds 12-hour average load by 28.3%. <br /> AED Excursion (amount by which peak exceeds 1.3 x average): 0 Btuh <br /> Definition: A system has adequate exposure diversity if the peak-hour glass load for the entire conditioned space does not <br /> exceed the average glass load for the entire conditioned space by more than 30 percent. <br /> C:\Program Files\Elite\Rhvacw\Projects\martinson.rhv Thursday, January 18, 2007, 3:50 PM <br />