Laserfiche WebLink
New Construction Energy Code Compliance Certificate RECEIVED <br /> Per NI 101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside Date Certificate Posted <br /> the building. The certificate shall be completed by the builder and shall list information and values of APR p f!p 12 Z 018 <br /> components listed in Table NI 101.8. rI U <br /> Mailing Address of the Dwelling or Dwelling Unit City, <br /> 2635 Casco Point Rd Wayzata CITY OF ORONO <br /> Name of Residential Contractor MN License Number <br /> Everlast Enter a rises B a S9 s(o (p <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> w <br /> oN <br /> 4) a <br /> oRctio d y>` Active(With fan and monometer or <br /> copy b o other system monitoring device) <br /> 07 N <br /> M Q W m U t <br /> C, a <br /> Ta -Insulation Location ? g, z " " c °' w x o <br /> c4 U g w <br /> is $ 'Fp 'o`n <br /> F g 272' 71 <br /> F ° at S z w w wrx Other Please Describe Here <br /> Below Entire Slab y <br /> Foundation Wall 9-15 /' ->< Type in locati .interior xterior or integral <br /> Perimeter of Slab on Grade — <br /> Rim Joist(Foundation) <br /> Type in location:interior exterior or integral <br /> Rim Joist(1 Floor+) Q-.2-0 <br /> Wall -.20Type in location: or xterior or integral <br /> �D x <br /> Ceiling,flat R-L-19 <br /> r4 1 '>< <br /> Ceiling,vaulted ( -LiCi X <br /> Bay Windows or cantilevered areas iR-3'3 " X X <br /> Bonus room over garage R.-3t X- iJ[o'- - --i-'do 4,--062,2ct ee 1;-)-7 <br /> Describe other insulated areas <br /> Windows a Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 32 X Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): --7(1 R-value <br /> MECHANICAL SYSTEMS II Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type Natural Gas Natural Gas _ Electric Passive <br /> Manufacturer Lennox AO Smith Lennox Powered <br /> IntSLP98UH070XV36B GPVL-50 XC2O-036-230 Describe: with exhaust device. <br /> ModelDescribe: <br /> Input in70,000 Capacity in 50 Output in <br /> Rating or Size BTUS: Gallons: 3 Other,describe: <br /> Tons: <br /> Heat Loss: 66 059 Heat Gain: <br /> Structure's Calculated ' 31,874 Location of duct or system: <br /> AFUE or 98% SEER: 13 <br /> HSPF% Lower Level <br /> Calculated 31874 <br /> Efficient coolin_load: ' �U Cfm's <br /> I (0" "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): Not required per mech.code <br /> Select Type X Passive:6"R8 Ins.Flex <br /> X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 108 High: 150 Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system: <br /> Continuous exhausting fan(s)rated capacity in cfms: <br /> Location of fan(s),describe: I Cfm's <br /> Capacity continuous ventilation rate in cfms: 72 4 bedroomsx15+15=75cfm 6 i i "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cfms: 144 3411 sq.ft.x.02=69cfm "metal duct <br /> Credted'Uy!PM version uozuusr <br />