Laserfiche WebLink
1 Rhw c-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> [Angell-Aire Glad#2(625 Ferndale) <br /> Burnsville,MN 55337 - _ _ Page 2 <br /> PLoad Preview Report <br /> Sens Lat Net Sens Win Sum Sys Duct <br /> LScope_ Area Gain Gain _ Gain Loss CFM CFM CFM Size <br /> Building: 4.15 Net Tons 5.02 Recommended Tons, 1,163 ft.2/Ton, 86.84MBH Heating _ <br /> Building 5,840 46,417 3,429 49,847 86,844 1;141 2,162 2,162 <br /> System 1: 4.15 Net Tons, 5.02 Recommended Tons,LL 1,163 ft.2/Ton, 86.84 MBH Heating <br /> System 1 5,840 46,417 3,429 49,847 86,844 1,141 2,162 2,162 20x19 <br /> Ventilation 275 870 1,146 1,598 <br /> Humidification 3,829 <br /> Zone 1 2,720 27,130 848 27,978 30,796 432 1,271 1,271 <br /> 1-Main Floor(old) 1,360 27,130 848 27,978 23,527 330 1,271 1,271 10-7 <br /> 3-Basement(old) 1,360 0 0 0 7,269 102 0 0 0-0* <br /> Zone 2 1,560 19,806 749 20,555 28,673 402 928 928 <br /> 2-Masterbed 1,560 19,806 749 20,555 28,673 402 928 928 7-7 <br /> Zone 3 1,560 16,473 962 17,435 21,948 308 772 772 <br /> 4-Bedrooms 1,560 16,473 962 17,435 21,948 308 772 772 6-7 <br /> Note: Since the system is multizone, the Peak Load Procedure was used to determine wall and glass sensible gains at the <br /> room level, so the sums of the room sensible gains and airflows for cooling shown above are not intended to equal the <br /> system totals. <br /> C:\Program Files\Elite\Rhvacw\Projects\LECY RE-MODEL.rhv Friday, August 29, 2014, 1:36 PM <br />