Daily safety checklist <br /> 4 Daily safety checklist <br /> These minimum safety checks should be made each day and after any loss of electri- <br /> cal power: <br /> 1. Activate the door. Door should open at a slow smooth pace (4 or more seconds), <br /> and stop without impact. <br /> 2. Door must remain fully open for a minimum of 5 seconds before beginning to <br /> close. <br /> 3. Door should close at a slow smooth pace (4 or more seconds), and stop without <br /> impact. <br /> • 4. Inspect the floor area. It should be clean with no loose parts that might cause user <br /> to trip or fall. Keep traffic path clear. <br /> 5. Inspect the door's overall condition. The appropriate signage should be present <br /> and the hardware should be in good condition. <br /> 6. Have door inspected by an AAADM certified inspector at least annually. <br /> DO NOT USE DOOR if it fails any of these safety checks or if it malfunctions in <br /> any way. Call a qualified automatic door service company to have door repaired <br /> or serviced. <br /> Apply to both sides of the door. <br /> AUTOMATIC when using a Wail switch, <br /> CAUTION apply to both sides of the door. <br /> Apply the push decal to the push <br /> DOOR <br /> OOpfl side and the pull decal to the pull <br /> side of the door. <br /> 1(111111 <br /> ea T <br /> LOW ENERGY <br /> POWER OPERATED Push plate r +I <br /> co <br /> DOOR j 1NI I LO <br /> CV 1 <br /> +I <br /> ACTIVATELO <br /> SWITCH TO M <br /> OPERATE <br /> PULL TO PUSH TO <br /> OPERATE OPERATE ---`` <br /> • <br /> 1003826-US-4.0 Issue 2008-11-13 7 <br />