My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Building Permit Application
Orono
>
Property Files
>
Street Address
>
G
>
Goldenrod Way
>
2860 Goldenrod Way - 33-118-23-24-0044
>
Misc
>
Building Permit Application
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:49:06 PM
Creation date
3/19/2020 2:52:02 PM
Metadata
Fields
Template:
x Address Old
House Number
2860
Street Name
Goldenrod
Street Type
Way
Address
2860 Goldenrod Way
Document Type
Misc
PIN
3311823240044
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Directions-The Minnesota Fuel Gas Code method to calculate to size of a required combustion air opening,is called the Known Air <br /> Infiltration Rate Method.For new construction,4b of step 4 is required to be filled out. <br /> IFGC Appendix E,Worksheet E-1 <br /> Residential Combustion Air Calculation Method <br /> (for Furnace,Boiler,and/or Water Heater in the Same Space) <br /> Step 1:Complete vented combustion appliance information. <br /> Furnace/Boiler: $DODO <br /> raft Hood Dan Assisted i� rirect Vent Input: Btu/hr or Power Vent <br /> Water Heater: 40000 <br /> raft Hood Z Fan Assisted Direct Vent Input: Btu/hr or Power Vent <br /> Step 2:Calculate the volume of the Combustion Appliance Space(CAS)containing combustion appliances. <br /> The CAS includes all spaces connected to one another by code compliant openings. CAS volume: 640 ft3 <br /> LXWXH ®L 10 W8JH <br /> Step 3:Determine Air Changes per Hour(ACH)1 <br /> Default ACH values have been incorporated into Table E-1 for use with Method 4b(KAIR Method).If the year of construction or ACH is not known,use <br /> method 4a(Standard Method). <br /> Step 4:Determine Required Volume for Combustion Air.(DO NOT COUNT DIRECT VENT APPLIANCES) <br /> 4a.Standard Method <br /> Total Btu/hr input of all combustion appliances Input: Btu/hr <br /> Use Standard Method column in Table E-1 to find Total Required TRV: ft3 <br /> Volume(TRV) <br /> If CAS Volume(from Step 2)is gre a ter th a n TRV then no outdoor openings are needed. <br /> If CAS Volume(from Step 2)is less than TRV then go to STEP 5. <br /> 4b.Known Air Infiltration Rate(KAIR)Method(DO NOT COUNT DIRECT VENT APPLIANCES) <br /> Total Btu/hr input of all fan-assisted and power vent appliances Input: 400000 Btu/hr <br /> Use Fan-Assisted Appliances column in Table E-1 to find RVFA: 3000 ft3 <br /> Required Volume Fan Assisted(RVFA) <br /> Total Btu/hr input of all Natural draft appliances Input: 0 Btu/hr <br /> Use Natural draft Appliances column in Table E-1 to find RVNFA: 0 ft3 <br /> Required Volume Natural draft appliances(RVNDA) <br /> Total Required Volume TRV =RVFA+RVNDA TRV= 3000 + 0 3000 TRV ft3 <br /> Step 5:Calculate the ratio of available interior volume to the total required volume. <br /> Ratio=CAS Volume(from Step 2)divided by TRV(from Step 4a or Step 4b) <br /> Ratio= 640 / 3000 = 0.21 <br /> Step 6:Calculate Reduction Factor(RF). <br /> RF=lminus Ratio RF=1- 0.21 — 0.79 <br /> Step 7:Calculate single outdoor opening as if all combustion air is from outside. 40000 <br /> Total Btu/hr input of all Combustion Appliances in the same CAS Input: Btu/hr <br /> (EXCEPT DIRECT VENT) <br /> Combustion Air Opening Area(CAOA): <br /> Total Btu/hr di vi d ed by 3000 Btu/hr per inz CAOA= 40000 /3000 Btu/hr per inz= 13.33 int <br /> Step 8:Calculate Minimum CAOA. <br /> Minimum CAOA=CAOA multiplied by RF Minimum CAOA= 13.33 x 0.79 = 10.49 in, <br /> Step 9:Calculate Combustion Air Opening Diameter(CAOD) <br /> CAOD=1.13 m ultiplied by the square root of Minimum CAOA CAOD=1.13 V Minimum CAOA= 3.65 in.diameter go up one inch in size <br /> if using flex duct <br /> 1 If desired,ACH can be determined using ASHRAE calculation or blower door test.Follow procedures in Section <br /> G304. <br />
The URL can be used to link to this page
Your browser does not support the video tag.