Building Permit Application
Orono
>
Property Files
>
Street Address
>
G
>
Goldenrod Way
>
2860 Goldenrod Way - 33-118-23-24-0044
>
Misc
>
Building Permit Application
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:49:06 PM
Creation date
3/19/2020 2:52:02 PM
Metadata
Fields
Template:
x Address Old
House Number
2860
Street Name
Goldenrod
Street Type
Way
Address
2860 Goldenrod Way
Document Type
Misc
PIN
3311823240044
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Sabre Plumbing&Heating 7815 <br /> PI mouth MN 55447 Pa e2 <br /> Project Report <br /> General Project Information <br /> Project Title: 7815 <br /> Designed By: Josh Gray <br /> Project Date: Wednesday, January 18, 2017 <br /> Client Name: David Weekley Homes <br /> Company Name: Sabre Heating And A/C <br /> Company Representative: Josh Gray <br /> Company Address: 15535 Medina Rd. <br /> Company City: Plymouth, Mn 55447 <br /> Company Phone: 763-473-2267 <br /> Company Fax: 763-473-8565 <br /> Company E-Mail Address: josh.gray@sabreheating.com <br /> Design Data <br /> Reference City: Minneapolis, Minnesota <br /> Building Orientation: Front door faces East <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 ft. <br /> Altitude Factor: 0.970 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -15 -12.38 n/a 30% 72 29.40 <br /> Summer: 88 73 50% 50% 75 35 <br /> Check Figures <br /> Total Building Supply CFM: 1,509 CFM Per Square ft.: 0.344 <br /> Square ft. of Room Area: 4,389 Square ft. Per Ton: 1,340 <br /> Volume (ft') of Cond. Space: 39,501 <br /> i <br /> Building loads <br /> Total Heating Required Including Ventilation Air: 58,251 Btuh 58.251 MBH <br /> Total Sensible Gain: 33,218 Btuh 85 % <br /> Total Latent Gain: 6,078 Btuh 15 % <br /> Total Cooling Required Including Ventilation Air: 39,295 Btuh 3.27 Tons(Based On Sensible+ Latent) <br /> {Motes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> M:\Sales and Estimating\Heat Calcs\David Weekley Homes\—UNTTLO.rh9 Wednesday, January 18, 2017, 3:21 PM <br />