Laserfiche WebLink
Ne'W Construction Energy Code Compliance Certificate <br /> Certificate Posted <br /> Per R401.3 Building Certificate.A building certificate shall be posted on or in the electrical distribution panel. Date 1/18/17 <br /> Mailing Address of the Dwelling or Dwelling Unit <br /> 7815 <br /> Name of Residential Contractor MN License Number <br /> David Weekley Homes <br /> Cit} Plan►D <br /> 7815 <br /> THERMAL ENVELOPE RADON CONTROL SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> C, <br /> y <br /> R COSY = T <br /> F- ti <br /> Active(With fan and monometer or <br /> .O T <br /> � � �o o � other system monitoring device) <br /> E a R <br /> Qv -0 Location(or future Location)of Fan: <br /> yy> T <br /> > ❑ ti ti R Lc. O <br /> Insulation Location <br /> Other Please Describe Here <br /> Below Entire Slab ix <br /> Foundation Wall R-10 X exterior <br /> Perimeter of Slab on Grade X <br /> Rim Joist(1st Floor) R-20 X Interior <br /> Rim Joist(2nd Floor) R-20 X Interior <br /> Wall R-20 X <br /> Ceiling,flat R-49 Ix <br /> Ceiling,vaulted R-30 X <br /> Bay Windows or cantilevered areas R-30 X <br /> Floors over unconditioned areas R-38 X <br /> Describe other insulated areas <br /> Building Envelope air Tightness: Ducts stem air tightness: <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: .27-.31 1 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): .25-.29 R-8 I R-value <br /> MECHANICAL SYSTEMS Make-up Air Select Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per meth.code <br /> Fuel Type NAT GAS NAT GAS R-41 OA Passive <br /> Manufacturer Bryant Rheem Bryant Powered <br /> Interlocked with exhaust device. <br /> Model 912SB48080S17 PROG5042NRH67Pv BA13NA042 Describe: <br /> Input in 80000 Capacity in 50 Output in 3.5 Other,describe: <br /> Rating or Size BTUS: Gallons: Tons: <br /> AFUE or 92% SEER or 13 Location of duct or system: <br /> Efficiency HSPF°/ EER <br /> HEAT LOSS HEAT GAIN COOLING LOAD <br /> RESIDENTIAL LOAD cALc 58251 33218 39295 <br /> c fin's <br /> rouecluct UK <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace Not required per meth.code <br /> Select Type X Passive <br /> Heat Recover Ventilator(HRV) Capacity in cfins: Low: High: Other,describe: <br /> X Energy Recover Ventilator(ERV)Capacity in cfins: Low: 30%=94 High: 60%=186 Location of duct or system: <br /> Balanced Ventilation Capcity in CFMS: furnace room <br /> Locations of Fans,describe: Cfin's <br /> Capacity continuous ventilation rate in cl ms: 90 5 "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cfins: 180 "metal d <br /> APR 1 `i 201$ <br /> CITY OF ORONO <br />