My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic System Site Plan
Orono
>
Property Files
>
Street Address
>
W
>
Wyndmere Road
>
1165 Wyndmere Rd - 26-118-23-41-0010
>
Septic
>
Septic System Site Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:18:39 PM
Creation date
3/2/2020 11:16:34 AM
Metadata
Fields
Template:
x Address Old
House Number
1165
Street Name
Wyndmere
Street Type
Road
Address
1165 Wyndmere Road
Document Type
Septic
PIN
2611823410010
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
View images
View plain text
r <br /> M S T S 9075 155"'STREET. <br /> A DIVISION OF WRM SERVICES INC. KIMBALL,MN 55353 <br /> (320)398-2705 <br /> June 9,2009 <br /> Kea Hong <br /> 1165 Wyndmere Road <br /> Orono,MN 55391 <br /> RE: Septic System Design for 1165 Wyndmere Road,Orono, MN <br /> Dear Kea <br /> As per your request,an onsite wastewater treatment system has been designed for the referenced <br /> property. It is our understanding that your existing system is non-compliant and you wish to upgrade it. <br /> The property was evaluated for it potential to support a standard septic system but due to limited space <br /> and high seasonal watertable no area could be found to support such a system. Therefore an Other type <br /> septic system has been designed in general accordance with Minnesota Rule Chapter 7080. <br /> The system will consist of using the existing two 1000 gallon septic tanks(provided they are inspected <br /> and found to be complaint), installing a 1300 gallon lift station and installing a 1260 pressure bed. An <br /> additional 500 gallon septic tank may be required to meet the city ordinance requirements but because <br /> they are existing and they meet the minimum requirements of chapter 7080 they may not require an <br /> additional septic tank to be installed. The proposed pressure bed area is to be over excavated to an <br /> elevation of 98.0 and filled with 1.2 feet of washed mound sand. The pressure bed is to be constructed <br /> on the washed sand. <br /> Soil borings were completed on the property and revealed fine sandy loam soil with a seasonal water <br /> table at an elevation of 96.2. With the bottom of the proposed pressure bed at an elevation of 99.2 the <br /> system will have the required three feet of vertical separation to the seasonal watertable. <br /> Because this system is classified as an Other type system semiannual monitoring and flow measurement <br /> will be required. For frequencies of the monitoring refer to the monitoring plan attached. Also attached <br /> is a mitigation plan. This plan lays out recommendations to follow if the system or a portion of the <br /> system fails or does not work properly. <br /> If you have any questions regarding the septic design feel free to contact me,I can be reached at 320- <br /> 398-2705 <br /> Sincerely, <br /> Miller's Sewage Treatment Solutions <br /> Bernie Miller <br /> MPCA Lic.No. 1921 <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).