Laserfiche WebLink
• ""' Septic System Management Plan <br /> ONSITE IN <br /> SEWAGE for In-Ground Systems UNIVERSITY OFMINNESOTA <br /> TREATMENT <br /> PROGRAM <br /> v � <br /> Professional Management Tasks <br /> These are the operation and maintenance activities that a pumper/maintainer performs to help ensure <br /> long-term performance of your system. Professionals should refer to the O/M Manual for detailed <br /> checklists for tanks,pumps, alarms and other components. Call 800-322-8642 for more details. <br /> ❑ Written record provided to homeowner after each visit. <br /> Plumbing/Source of Wastewater <br /> ❑ Review the Water Use Appliance Chart on Page 5 with homeowner. Discuss any changes in <br /> water use and the impact those changes may have on the septic system. <br /> ❑ Review water usage rates(if available)with homeowner. <br /> Septic Tank/Pump Tanks <br /> ❑ Manhole lid. A riser is recommended if the lid is not accessible from the ground surface.Insulate <br /> the riser cover for frost protection. <br /> ❑ Liquid level. Check to make sure the tank is not leaking.The liquid level should be level with the <br /> bottom of the outlet pipe. (If the water level is below the bottom of the outlet pipe, the tank may <br /> not be watertight. If the water level is higher than the bottom of the outlet pipe of the tank, the <br /> effluent screen may need cleaning,or there may be ponding in the drainfield.) <br /> ❑ Inspection pipes.Replace damaged caps. <br /> ❑ Baffles. Check to make sure they are in place and attached, and that inlet/outlet baffles are clear <br /> of buildup or obstructions. <br /> ❑ Effluent screen.Check to make sure it is in place;clean per manufacturer recommendation. <br /> ❑ Alarm. Verify that the alarm works. <br /> ❑ Scum and sludge.Measure scum and sludge in each tank,pump if needed. <br /> Pump <br /> ❑ Pump and controls. Check to make sure the pump and controls are operating correctly. <br /> ❑ Pump vault. Check to make sure it is in place;clean per manufacturer recommendations. <br /> ❑ Alarm.Verify that the alarm works. <br /> ❑ Drainback. Check to make sure it is operating properly. <br /> ❑ Event counter or run time. Check to see if there is an event counter or run time log for the pump. <br /> If there is one, calculate the water usage rate and compare to the anticipated average daily flow <br /> listed on Page 4. <br /> Soil Treatment Area <br /> ❑ Inspection pipes. Check to make sure they are properly capped. Replace caps that are damaged. <br /> ❑ Surfacing of effluent. Check for surfaced effluent or other signs of problems. <br /> ❑ Gravity trenches. Check the number of gravity trenches with ponded effluent. Identify the <br /> percentage of the system in use. Determine if action is needed. <br /> All other components—inspect as listed here: <br /> -3 - <br />