Laserfiche WebLink
CITY of ORONO <br /> Municipal Offices <br /> Street Address: Mailing Address: <br /> ��9$EgHOg' 2750 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, MN 55323.0066 <br /> Owner: �ern Address: 1150 Wyndmere Rd. <br /> Permit #'s: 1889 Dates: 8/5/68 Contractors: Sullivan <br /> (This is [x] an existing system [ ] new construction) <br /> YSTEM COMPLIANCE (1-3) : 1 <br /> Code System: Meets or exceeds current City standards in all respects relating to design, <br /> 1 , <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, located, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> 3 Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than three feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [ ] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 6 <br /> � Pumpout not needed at this time. <br /> /6J Solids accumulation in tanks indicates they should be pumped out this year. <br /> System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> 8 Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three years, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are [ ] or are not [ ] water tight or the condition is [)j unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> AINFIELD CONDITION (11-14) : 11 <br /> 1 Drainfield is dry, no surfacing evident. <br /> 2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 3 feet and the system is compliant. <br /> 2 X)9 g r4�4�I ml <br /> Date of Inspection -"Ye-Vi System nspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 a FAX 473-0510 <br />