Laserfiche WebLink
O <br /> CITY of ORONO <br /> Municipal Offices <br /> v, L ►�G Street Afress: q 5a.-a4 9-4160 O Mailing Address: <br /> tfl�' 2150 Kelley Parkway P.O. Box 66 <br /> Orono, MN 55356 Crystal Bay, 55323.0066 <br /> To Current Owner: Address: I ISO �* )(4 o-�.f�- <br /> City Ordinance 199 requires that each existing on-site sewage treatment system in Orono be inspected every two years. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the categories checked below. <br /> SYSTEM CONFORMITY (1-3): 1 <br /> "CODE 1 SYSTEM"_An ISIS which x6ects all the location,design and construction standards of the cuttent Orono Municipal Code. <br /> 2 "COMPLIANT SYSTEM" An ISIS which does not meet all the location,design and construction standards of the current Orono <br /> Municipal Code but does meet the three foot separation requirement or two foot requirement for systems installed 1996 or earlier,and <br /> which is not f fling or an imminent threat to public health or safety. <br /> 3 "NON-COMPLIANT SYSTEM" A prohibited ISTS;an ISIS located within a designated 100-year flood plain,any ISTS which may <br /> or may not meet all the location,design,or construction standards of the current Orono Municipal Code and which is failing for any <br /> reason;and any ISIS with less than three feet of unsaturated soil or sand between the distnbubon device and the limiting soil characteristics. <br /> TANK CONDITION(5-7): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Septic tanks must be pumped out this year (city code recommends tanks to be pumped out once every 3 years. <br /> Tank was last pumped ). <br /> Make sure septic tanks are pumped through manhole and not through white inspection Pipes. This allows for the proper <br /> cleaning. Kcep water sooner and iron filter discharge out of septic system to prolong life of drainfwK Ask pumper to test <br /> alarm float to verify alarm is still working in your house. The alarm warns owner that sePtage is about to backup into basement. <br /> 7 Inspection risers missing-tanks could not be inspected. Inspection risers(4"dia.pipe)must be installed in each tank. If <br /> tanks have not been pumped out within the last three years,they should be pumped out now. <br /> DRAIPIFIELD CONDITION 8-10 : <br /> Dminfiekl is dry,no surfacing evident. <br /> 9 Some evidence of surfacing,not critical yet. <br /> 10 Drainfield is saturated and visibly discharging untreated eluent to the surface. Contact the City Inspector <br /> immediately.Repairs must be completed within%days. <br /> COMMENTS: Qc�; _�i� `Odll� CT U st �.� 4,43 <br /> Date of Inspection Matt Bolterman- Septic System Inspector <br /> Note: In the eves that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property,be advised that this report does <br /> not guarantee or certify that an existing system will continue to fimction properly, but is merely an opinion of the adequacy of the system under current <br /> conditions based on the available information. <br />