Laserfiche WebLink
207 CLOSET <br /> 1 1 McGUIRE RESIDENCE 1 <br /> 1 HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES <br /> ROOM: 1207 CLOSET ' I jHEIGHT: j 8.5 <br /> FLOOR 1 21 1 1 ;AREA: j 216 VOLUME: 1,836 <br /> OCCUPANTS: 0 <br /> j I HEAT LOSS <br /> ELEMENT I AREA X MULTIPLIER 1= IBTU/HR <br /> ROOF 216 1S.F 2.2.Btu/Hr/S.F� 475 <br /> DOORS j 0 57 , - <br /> WINDOWS 75 1" 57 " , 4,275 <br /> WALLS 1 180 5 " 1 1 900 <br /> FOUNDATION i 0 7.5 " I - 1 <br /> INFILTRATION* I 8 CFM 1 102.6 Btu/Hr/CFM 785_ <br /> TOTAL: 6,435 <br /> VENTILATION** I 0 CFM 102.6 Btu/Hr/CFM - <br /> TOTAL 6,435 <br /> 1 I <br /> HEAT GAIN SENS. LATENT TOTAL <br /> ROOF I 216 S.F. 1 0.92 Btu/Hr/S.F. 199 199 <br /> DOORS S&W 0 (" 1 1001 " f ! - ) 1 - <br /> DOORS N&E 0 91 " - - <br /> WINDOWS S&W 50 " 1001 " 5,000 5,000 <br /> WINDOWS N 0 I 91 - - <br /> WINDOWS E 25 601 1,500 ! 1,500 <br /> WALLS 1 S&W I 103 1 1.91 " 196 I 196 <br /> WALLS IN 77 ;" j 0.81 " 1 62 62 <br /> WALLS 1E • 0 0.81 - 1 - <br /> LIGHTS I 1 0 3.4151*** I - - <br /> EQUIPMENT 0 jKW 3415 Btu/kw - - <br /> OCCUPANTS 0 I**** 300/3001***** - - - <br /> INFILTRATION 8 'CFM 16/251Btu/hr/CFM 122 191 314 <br /> j TOTAL: 1 7,078 191 7,270 <br /> VENTILATION 1 0 1CFM 16/25jBtu/hr/CFM - - - <br /> 1 TOTAL: I 7,078 191 7,270 <br /> NOTES: <br /> I i <br /> Infiltration based on 1/4 air changes per hour <br /> *** Lighting heat gain based on 1 watt per square foot <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry <br /> ****Occupants normally in continuous use of area <br /> Sensible and Latent load-based on light activity unless noted otherwise! <br /> Page 1 <br />