Laserfiche WebLink
112 STAIRS <br /> 1 1 1 McGUIRE RESIDENCE I 1 <br /> 1 ! HEAT LOSS AND GAIN CALCULATIONS FOR INDIVIDUAL SPACES 1 <br /> ROOM: 1112 STAIRS 1 1 HEIGHT: 1 8.5 <br /> FLOOR 1 AREA: 1 225 1VOLUME:; 1,913 <br /> OCCUPANTS: 10 j <br /> HEAT LOSS i <br /> ELEMENT AREA; X MULTIPLIER = BTU/HR <br /> ROOF j 0 !S.F 2.2jBtu/Hr/S.F - <br /> DOORS 1 0 571 " 1 - <br /> WINDOWS 36 " 571 " 2,052 <br /> WALLS 1 219 " 5 " 1 1,095 <br /> FOUNDATION 0 7.5 - <br /> INFILTRATION* 8 CFM 102.6 Btu/Hr/CFM 818 <br /> 1 1 TOTAL: 3,965 <br /> VENTILATION** 0 CFM I 102.6 Btu/Hr/CFM 1 <br /> 1 j TOTAL I 3,965 j <br /> 1 1 I I <br /> 1 HEAT GAIN 'SENS. LATENT 1TOTAL <br /> ROOF 0 S.F. i 0.92 Btu/Hr/S.F. - 1 - <br /> DOORS 1S&W 1 0 " 1001 " ! I - i j - <br /> DOORS IN&E 0 91 " 1 1 - - <br /> WINDOWS S&W 36 " 1001 " I ! 3,600 ; 3,600 <br /> WINDOWS N 0 1" 9j " j - - <br /> WINDOWS E 0 1 60! " - - <br /> WALLS 1 S&W 219 I" 1.91 " I 416 416 <br /> WALLS IN 1 0 1" 0.81 " 1 - - <br /> WALLS 1E 7 <br /> 1 0 1 0.81 1 - - <br /> LIGHTS i 1 0 1" 3.4151*** 1 - - <br /> EQUIPMENT 0 KW 34151Btu/kw 1 - - <br /> OCCUPANTS 0 1**** 1 300/3001 1 - - - <br /> INFILTRATION 8 i CFM 1 16/251Btu/hr/CFM 128 199 327 <br /> ( 1 TOTAL: 1 4,144 1991 4,343 <br /> VENTILATIONi 0 1CFM 16/25IBtu/hr/CFM - - - <br /> 1 TOTAL: ( 4,144 I 199 I 4,343 <br /> NOTES: 1 <br /> Infiltration based on 1/4 air changes per hour ', <br /> ***Lighting heat gain based on 1 watt per square foot 1 1 , <br /> **Ventilation based on 2 CFM per S.F. Bathroom or Laundry ', <br /> ****Occupants normally in continuous use of area <br /> Sensible and Latent load- based on light activity unless noted otherwise: <br /> Page 1 <br />