Laserfiche WebLink
. T <br /> ' <br /> LengthWALL-BRACING OEM <br /> Calculator <br /> i <br /> 0 Report Appiication Issues or Provide Customer Feedback 0AtpaJ/app.smarWw t.com/bffortn? 0 A....+%AMM n <br /> 2012 IRC Required Bradt-Wall-Line Length Calculations <br /> PROJECT INFORMATION <br /> NAME:SASMKNT SIDE TO SIDE <br /> ADDRESS:1140 WVWDMERE ROAD,ORONO <br /> WALL DIRECTION:Side To Side <br /> SEMM DEEM CATEGORY:A <br /> RA91C WIND SPEED:00 rrrph <br /> WIND EXPOSURE CATEGORY:B <br /> Wag Line 1-1 V d Line 2-1 Way Line 3-1 <br /> lin I <br /> Braced-Wall-IJns Location 1 at of 2-310ry let of 2-story 1 at of 2-story <br /> Eave to Ridge Height left 19 ft loft <br /> Braced-Wall-line Spacing 44.83 ft 35.92 ft 27.00 ft <br /> Way Height 9 ft 9 ft 9 ft <br /> Bracing Method CS-WSP CS-WSP CS-WSP <br /> GB Cawtruction Type WA WA WA <br /> Gypsum Way Board on Inside Yea Yes Yes <br /> Hodzontal Joints Blocked Yes Yes Yes <br /> Holdown Device Used No No No <br /> WIND <br /> Tabulated Wind Bracing Amount 132075 ft 10.776 ft 8.25 It <br /> B o urs Heft Factor 1 1 1 <br /> Eays-t Ridge Height Factor 1.24 127 127 <br /> Wind WWI Height Factor 025 0.95 0.95 <br /> Number of BWL Factor 1.3 1.3 1.3 <br /> Holdown Factor 1 1 1 <br /> Blocked Joint F 1 1 1 <br /> Gypsum on Inside Factor 1 1 1 <br /> Wind GB Construction Factor 1 1 1 <br /> Required Wind Bmdng Amount 20.23 It 16.91t 12.94 It <br /> RESULTS <br /> Length of Wei 13rsoing Regeted 2MM ft te.91t 1294 ft <br /> NOTES <br />