My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017-01591 - new structure
Orono
>
Property Files
>
Street Address
>
W
>
Wyndmere Road
>
1140 Wyndmere Road - 26-118-23-41-0014
>
Permits/Inspections
>
2017-01591 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:18:48 PM
Creation date
2/26/2020 2:31:45 PM
Metadata
Fields
Template:
x Address Old
House Number
1140
Street Name
Wyndmere
Street Type
Road
Address
1140 Wyndmere Road
Document Type
Permits/Inspections
PIN
2611823410014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 OEM COPY <br /> Length <br /> 0 Report Application Issues or Provide Customer Feedback(httpsJ/app.smartsheet.com/b/forrn? 0 •1 •. 14101 n <br /> 2012 IRC Required Braced-Wal I Aine Length Calculations <br /> PROJECT INFORMATION <br /> NAME:1ST Floor FRONT TO BACK <br /> ADDRESS:1140 WYNDMERE ROAD,ORONO <br /> WALL DIRECTION:Front to Back <br /> SEISMIC DESIGN CATEGORY:A <br /> BASIC WIND SPEED:90 mph <br /> WIND EXPOSURE CATEGORY:B <br /> Wall Line A-1 Well Line B-1 Wall Line C-1 Well Line D-1 <br /> lI°puts <br /> Braced-Wall-Une Location 1st of 1-story 1st of 1-story 1st of 1-story 1st of 1-story <br /> Fave to Ridge Height 16 ft 19 ft 19 ft 19 ft <br /> Braced-Wall-1 Ine Spacing 21.42 It 26.00 ft 22.29 It 14.00 ft <br /> Well Height lift lift lift loft <br /> Bracing Method CS-WSP CS-WSP CS-WSP CS-WSP <br /> GB Construction Type N/A WA N/A N/A <br /> Gypsum Wall Board on Inside Yes Yes Yes Yes <br /> Horizontal Joints Blocked Yes Yes Yes Yes <br /> Holdown Device Used No No No No <br /> WIND <br /> Tabulated Wind Bracing Amount 3.713 ft 4.4 It 3.8435 ft 2.6 ft <br /> Exposure Height Factor 1 1 1 1 <br /> Fave-to-Ridge Height Factor 1.38 1.54 1.54 1.54 <br /> Wind Wall Height Factor 1.05 1.05 1.05 1 <br /> Number of BWL Factor 1.45 1.45 1.45 1.45 <br /> Holdown Factor 1 1 1 1 <br /> Blocked Joint Factor 1 1 1 1 <br /> Gypsum on Inside Factor 1 1 1 1 <br /> Wind GB Construction Factor 1 1 1 1 <br /> Required Wind Bracing Amount 7.69 ft 10.32 ft 9.01 It 5.81 ft <br /> RESULTS <br /> Length of Well Bracing Required 7.M ft 10.32 ft 9.01 ft 5.81 ft <br /> NOTES <br /> RECEIVED <br /> tj_C 0 5 LU1l <br /> CITY OF ORONO <br />
The URL can be used to link to this page
Your browser does not support the video tag.