My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 HVAC floor plan
Orono
>
Property Files
>
Street Address
>
W
>
Woodhill Road
>
200 Woodhill Rd - 02-117-23-12-0001 Country Club
>
Survey
>
2000 HVAC floor plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:06:16 PM
Creation date
2/25/2020 1:06:26 PM
Metadata
Fields
Template:
x Address Old
House Number
200
Street Name
Woodhill
Street Type
Road
Address
200 Woodhill Rd
Document Type
Survey
PIN
0211723120001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONCRETE SLAB <br />GOND-1 <br />3 DX <br />3' <br />• , <br />OPENINGin VALVED <br />FOR PLUMBER <br />1" <br />2 PSI GAS METER. <br />2 <br />1148 CFH TOTAL <br />CONNECTED LOAD <br />270 MUA) <br />500 AHU-1 do 2) <br />378 KITCHEN APPL.)106 <br />UNIT# <br />DX <br />G- <br />_ 1 3�8" SUCTION_ <br />3/4 LIQUID <br />STORAGE ROOM --- — _ _ ' <br />1212 MUA DIFF---- <br />MFQ'R <br />MODEL <br />CFM <br />AREA SERVED <br />COOLING TONS <br />w ' <br />x <br />0 <br />1 <br />2412 MUA DIFF. <br />550 CFM EA___ <br />(4) THUS <br />MUA <br />PANE <br />KITCHEN EXHAUST <br />HOOD <br />20X10 CONNECTION <br />�TOH <br />-f <br />3' <br />DECK <br />41X38 0/A LOUVER <br />W/ 6X38 PORTION <br />TO BE USED FOR _ <br />COMBUSTION AIR. <br />— _ 3I4» G----a—� <br />t! <br />!11 <br />U-1 !! <br />!! <br />10" FLUE UP ! ' <br />THRU ROOF !' a <br />1 <br />AIR HANDLER UNIT SCHEDULE <br />UNIT# <br />LOCATION <br />MFQ'R <br />MODEL <br />CFM <br />AREA SERVED <br />COOLING TONS <br />HTG. IN <br />HTG. OUT <br />VOLTAGE <br />GAS CONN. WEIGHT <br />I240/3 I3/4" <br />REMARKS <br />GREENHECK <br />G -85—D PRV <br />240 <br />3/8" 1/20 <br />120/1 <br />BACK DRAFT DAMPER <br />EF -2 <br />ROOF <br />I250,000 <br />I200,000 <br />CUBE 180 UPBLAST <br />2400 <br />AHU-1 <br />ATTIC <br />TRANE <br />GSAA <br />4000 <br />ASSEMBLY ROOM <br />10 <br />765 <br />SMOKE DETECTORS, ECONOMIZER, TWO STAGE GAS <br />AHU-2 <br />ATTIC <br />THANE <br />GSAA <br />4000 <br />ASSEMBLY ROOM <br />10 <br />250,000 <br />200,000 <br />240/3 <br />3/4" 765 <br />SMOKE DETECTORS, ECONOMIZER, TWO STAGE GAS <br />EXHAUST FAN SCHEDULE <br />UNIT# <br />LOCATION <br />SYSTEM <br />MFG'R <br />MODEL • STYLE <br />CM <br />S.P. H.P. <br />VOLTAGE <br />REMARKS <br />EF -1 <br />ROOF <br />TOILET EXHAUST <br />GREENHECK <br />G -85—D PRV <br />240 <br />3/8" 1/20 <br />120/1 <br />BACK DRAFT DAMPER <br />EF -2 <br />ROOF <br />HOOD EXHAUST <br />GREENHECK <br />CUBE 180 UPBLAST <br />2400 <br />1 1/2" 1 <br />240/3 <br />GREASE RATED, VENTED CURB EXTENSION, HINGE KIT <br />EXTERNAL <br />._ "'/INSULATION <br />20X48 R/A GRILLE <br />AT CEILING. <br />TYPICAL (2) UNITS <br />AHU-2 III <br />150 CFM i 1 3/8"UCTION — <br />--------------------, ( i 3/4" LIQID- — — <br />s -- ------ a DX DX <br />3 F~ f <br />— �s �` 20 <br />1 ! ! ! <br />4€ ' <br />{ 1 i CON <br />_-3/4 <br />DX 1! t <br />120 i 1! i. i t! COOLING COIL <br />� I t <br />. 412 SAD 1+ I i a 1 LOW CEILING AREA <br />p <br />00 CMmum 0 <br />-� t-.---- _ _ - <br />- t 1 I I <br />_ � I SURFACE MOUNT <br />KITCHEN^------ _ _ _ �� --- — ------ i ! t DIFFUSERS TO t ' <br />--------------- i 1 1 _ WOOD CEILING <br />105 I � --- --- _ I I <br />i �Fy <br />% <br />--------------1 <br />EXTERNAL a 1 1 <br />INSULATION <br />T EXTERNAL <br />rill, <br />INSULATION <br />°WOMENS ROOMWATER 14x14 WE <br />104 HEATER EXHAUST DUCT I a ! ! ! I 1 <br />UP TO PRV <br />EF- 1_ =----------- ---------------- - - - - -- ---------- - - - - -- <br />80 <br />:1212...SAD 1 - <br />1202C MG "'120'-C 1 <br />I i 1 <br />'1 <br />MENS ROOM I2414 SAD <br />Q103 CD _� -- 2414 SAD 1000 CM <br />I 1-810 HM EA 1 '''�' HC (4) THUS <br />y <br />k 8} <br />20' <br />FLOOR PLAN HVAC <br />AIR COOLED CONDENSING UNIT <br />UNIT# <br />LOCATION <br />MFG'R <br />MODEL <br />BTU <br />CM <br />VOLTAGE <br />H.P. <br />UNIT <br />MFG'R MODEL <br />COOLING TONS <br />MCA <br />CIRCUIT BRKR. <br />VOLTAGE <br />WEIGHT <br />REMARKS <br />COND-1 <br />TRANE TTA120C <br />10 <br />49.4 <br />60 AMPS <br />240/3 <br />480 <br />INTERLOCK W/ HOOD EXH. FAN <br />COND-2 <br />TRANE TTA120C <br />10 <br />49.4 <br />60 AMPS <br />240/3 <br />480 <br />---------- <br />------1212 <br />1212 EAG <br />1212 SAD <br />VAULTED CEILING AREA <br />})qE <br />120 CM <br />120 CFM <br />1 EXPOSED STRUCTURE 1 <br />** <br />-- — — <br />— — —— — <br />— — — — —— <br />DROP <br />COAT ROM l <br />� ' <br />EXPOSED DUCT <br />1a2 i <br />a � <br />— — — — — -- <br />— — — — — — — <br />1212 <br />SAD <br />t 1 <br />120 CM <br />ENTRY VESTIBULE <br />r. <br />r <br />-------------------- <br />___ <br />101 <br />i <br />20' <br />FLOOR PLAN HVAC <br />AIR COOLED CONDENSING UNIT <br />UNIT# <br />LOCATION <br />MFG'R <br />MODEL <br />BTU <br />CM <br />VOLTAGE <br />H.P. <br />UNIT <br />MFG'R MODEL <br />COOLING TONS <br />MCA <br />CIRCUIT BRKR. <br />VOLTAGE <br />WEIGHT <br />REMARKS <br />COND-1 <br />TRANE TTA120C <br />10 <br />49.4 <br />60 AMPS <br />240/3 <br />480 <br />INTERLOCK W/ HOOD EXH. FAN <br />COND-2 <br />TRANE TTA120C <br />10 <br />49.4 <br />60 AMPS <br />240/3 <br />480 <br />GAS MAKE-UP AIR UNIT SCHEDULE <br />UNIT# <br />LOCATION <br />MFG'R <br />MODEL <br />BTU <br />CM <br />VOLTAGE <br />H.P. <br />S.P. <br />GAS CONN. <br />WEIGHT <br />REMARKS <br />MUA-1 <br />SLAB <br />RUPP <br />RAM -10 <br />270,000 <br />2500 <br />240/3 <br />2 <br />1.15 <br />1/2" <br />1080 <br />INTERLOCK W/ HOOD EXH. FAN <br />GENERAL NOTES: <br />1. ALL GAS PIPING TO BE SCHEDULE 40 GALVANIZED WITH <br />THREADED FITTINGS 2" AND SMALLER. FITTINGS LARGER <br />THAN 2" TO BE WELDED. <br />2. LOCATE STRUCTURAL FRAME OPENINGS <br />TO MAINTAIN FULL CLEARANCE WITHIN <br />CURB I.D. DIMENSIONS. <br />3. CONCEALED DUCTWORK SHALL BE EXTERNALLY WRAPPED <br />WOODHILL COUNTRY CLUB <br />N® d MN <br />BARN REMODELING <br />FLOOR PLAN - HVAC <br />REVISIONS <br />m <br />AW _ <br />I! <br />PY <br />LIVV V G VIV VLR IlG V� IfIL JI/"11L <br />ian4'ry F I N SQTA. <br />0 CO <br />DATE '� � REG. N0. 24742 <br />THIS D ING IN DESIGN AND DETAIL IS OUR <br />PROPERTY AND MUST NOT BE USED EXCEPT <br />IN CONNECTION WITH OUR WORK. ALL RIGHTS <br />OF DESIGN AND DETAIL ARE RESERVED. <br />1�Q�M'Je� (y_t2-of <br />CHECKED BY: WHH <br />DRAWN BY: RMH <br />DATE: 7/ 13/00 <br />PROJECT MGR: WHH <br />M-1 <br />J01 -1t0 <br />E00-1 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.