My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic System Info
Orono
>
Property Files
>
Street Address
>
W
>
Woodhill Avenue
>
1255 Woodhill Avenue - 02-117-23-24-0011
>
Septic
>
Septic System Info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:07:46 PM
Creation date
2/25/2020 10:29:02 AM
Metadata
Fields
Template:
x Address Old
House Number
1255
Street Name
Woodhill
Street Type
Avenue
Address
1255 Woodhill Ave
Document Type
Septic
PIN
0211723240011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> PIGGY BACK PLUG IN WEATHER ALARM WIRE FROSTPROOFING THE DROP BOX <br /> PROOF ENCLOSURE-OR LOCATE \ MANHOLE COVER SECURED <br /> IN HOUSE BASEMENT DISCHARGE PIPE x.,r. 12 SOIL COVER , ' <br /> POWER SUPPLY------ 4 EN\ PREVENT UNAUTHORIZED _ <br /> CONTROL WIRE------1ENTRY 1 PLACE A ROCK ENVELOPE `+ 3/a 2'/2 DIA. HOCK <br /> PUMP POWER CORD-- Vtr —DRAIN TILE OR RIGID <br /> AROUND DISCHARGE PIPE. LFROM PUMP/ <br /> 24"MANHOLE J1 • ROCK SHOULD BE 34 TO 2'/2 f 3' MIN. FROM PERBOTTOM OF TRENCHFORATED PLASTIC I TO <br /> tNii ( INCHES IN DIAMETER, WITH <br /> FROM t I , 1OR <br /> ' UNION OTHER WATER TABLE OR CLAY OR ROCK <br /> ST <br /> i_ QUICKODISCONNECTRNO SAND. COVER WITH A 2 LAYER <br /> SEAL ALARM FLOAT ON SEPARATE FITTING INCH THICK SHEET OF <br /> TANK ELECTRICAL CIRCUIT <br /> EXPANDED POLYSTYRENE. <br /> RESERVE CAPACITY WHEREVER POSSIBLE MAIN- <br /> TO SOIL <br /> AFTER ALARM SOUNDS O <br /> I -"-TREATMENT TAIN A GRASS COVER OVER SOIL TREATMENT AREAS FOR TYPE I HOMES° <br /> AREA TOP OF TRENCH AND ALLOW <br /> START LEVEL S7 �:,,_ _ _ '/4 WEEPHOLE FOR SNOW TO REMAIN IN PLACE. REQUIRED SOIL TREATMENT AREA <br /> {—.. --- 3•) ORAINBACK;OR WHEN SNOW COVER IS LIGHT, IN SQUARE FEET PER BEDROOM <br /> — - — CHECK VALVE MAY <br /> • <br /> IBE INSTALLED IF PLACE A 6 INCH HAY OR PERCOLATION <br /> SMUT-OFF LEVEL Sj__ PIPE TO TREATMENT RATE IN TRENCHES <br /> F <br /> AREA IS FROST STRAW LAYER ON GROUND <br /> r PROOF MINUTES PER <br /> 12"-18"MINIMUM DEPTH �_ ABOVE PIPE. INCH SEEPAGE DEPTH OF ROCK BELOW <br /> E0001 BEDS DISTRIBUTION PIPE, IN INCHES <br /> PUMPABLE CAPACITY <br /> AT LEAST 75 GALLONS 'i ov 6 12 18 24 <br /> BACKFILL <br /> EXPANDED FASTER — — — — — <br /> POLYSTYRENE ���' b . <br /> PUMPING RATE SHOULD NOT EXCEED DROP BOX ./ THAN 0.1 <br /> OUTFLOW CAPACITY OR 45 GALLONS PER MINUTE DISCHARGE 0.1 TO 5 125 125 100 85 75 <br /> (2700 GALLONS PER HOUR). 6 TO 15 190 190 150 125 115 <br /> PUMP DISCHARGE HEAD MUST BE ADEQUATE TO ROCK 3/4"-21/2" DIA. <br /> OVERCOME ELEVATION DIFFERENCE BETWEEN THE 16 TO 30 250 250 200 165 150 <br /> PUMP AND DISTRIBUTION BOX PLUS FRICTION LOSS <br /> IN DISCHARGE PIPE. 31 TO 45 300 300 240 200 180 <br /> 46 TO 60 330 330 265 220 200 <br /> LIQUID CAPACITIES OF VERTICAL CIRCULAR TANKS SLOWER _ _ <br /> • THAN 60b _ <br /> INSIDE DIAMETER OF TANK GALLONS PER FOOT <br /> IN FEET OF DEPTH °SEWAGE FLOW • 150 GPD PER BEDROOM <br /> TO DETERMINE THE LIQUID SPECIAL DESIGN SHOULD BE USED TO PROVIDE ADEQUATE <br /> 1.5 13 O TREATMENT AND ABSORPTION OF EFFLUENT <br /> 2 O 23 5 CAPACITY OF ANY TANK, FIRST <br /> DETERMINE THE SURFACE AREA <br /> 2.5 37.0 OF THE LIQUID. MULTIPLY <br /> 3.0 53.0 THIS VALUE BY 7.5 (GALLONS <br /> 4.0 94.0 PER CUBIC FOOT) TO DETER- RECOMMENDED AMOUNT OF EFFLUENT TO PUMP <br /> PER <br /> IS <br /> PERCENT <br /> 5.0 147.0 MINE THE TANK LIQUID MINIMUM AMOUNTOFOILSEWAGE <br /> EFFLUENTTO PUMPPER <br /> W <br /> 6.0 213.0 CAPACITY IN GALLONS PER CYCLE IS 75 GALLONS. <br /> FOOT OF DEPTH. <br /> FOR EXAMPLE, A CIRCULAR TANK WITH AN INSIDE <br /> DIAMETER OF 4 FEET HAS 94 GALLONS OF LIQUID <br /> CAPACITY PER FOOT OF DEPTH. , <br /> TO PUMP 200 GALLONS PER CYCLE, THE PUMP <br /> CONTROL SWITCHES WOULD NEED TO BE SET 2.1 <br /> UNIVERSITY OF MINNESOTA <br /> (200/94) FEET APART. EXTENSION AGRICULTURAL ENGINEERING <br /> '":n 'y 1 of <br /> • <br /> PUMPING STATION c'!� `;2, No. <br /> . 3. <br />
The URL can be used to link to this page
Your browser does not support the video tag.