Laserfiche WebLink
gv ,iti----- <br /> CITY OF ORONO 0 <br /> Municipal Offices `O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 ',('1/4. -4'',' <br /> '' f ON—SITE SEWAGE TREATMENT <br /> j4 INSPECTION REPORT <br /> • <br /> 9ktsilea <br /> Owner: /{4 i/ / /Xj Address: US Z. JOJ/1ct/pr. be; <br /> Permit #'s: SOS' Dates: Z,2—/ -----7'? Contractors: ( Jov r r AO/ C0 <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is IX an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): ' <br /> "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic [ ] has or 14 has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): Jr))Tank inspection indicates`:' <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped <br /> •- 0� out now. <br /> Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): !J <br /> D ' field inspection indicates: <br /> V1Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks,etc.): �� <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.) al <br /> :/ /)a ��,1 <br /> COMMENTS: A - �r� 1*1 . AWL ,f 3/ <br /> vin 9- ( av,r3/ : OJ L pi'M p ) <br /> SZ391P-• . , ' Wt2 e;;,. -rn - T <br /> 37/-93 l /Gc^rllW�" <br /> Date of Inspection AV------ // <br /> c System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />